4. Adjustments
Confidential: FUJIFILM Service Center Use Only
Lens Holder
Lens Base Plate
Lens Stand
Attention when conversion lens is used.
Convex side : Subject side.
Plane : Camera lens side.
Washer
(Plastic)
Fixed Ring
4-14. AF Adjustment
<Settings for AF Adjustment>
(1) Set up the EFA chart and conversion lens so that they are 500 ± 5 mm apart.
(2) Position the chart so that the brightness of the chart surface is between 1000 ± 200 LUX.
(3) Position the 500 mm conversion lens 25 ± 2 mm from the front end of the lens.
<EFA chart>
EFA chart
Fluorescent
light stand
Center
500mm conversion lens
500 ± 5 mm
Camera
25±2 mm with the zoom set to wide.
Note that the camera lens should not touch
the conversion lens.
<Step 1>
Insert the adjustment SD card into the camera, set the Mode dial to "
q
" and then turn the camera on.
<Step 2>
When the screen shown on the right appears, press the
Down button to change to "3".