4-4
4. Adjustments
Confidential: FUJIFILM Service Center Use Only
4-4.
Calibration method of pattern box
<Use the pattern box for Camera adjustment>
Turn on the power supply in the pattern box.
Afterwards, wait for about ten minutes so that the source of
light may stabilize.
(1) Brightness
180 ± 5 cd/m
2
(with LB140 filter)
No chart, center of pattern box
Minolta brightness meter LS-110 or equivalent
* Calibration method
Place the filter (LB140) against the pattern box. With
the filter (LB140) in contact with the brightness meter,
adjust the pattern box brightness to 180 ± 5
cd/m
2
.
(2) Color temperature
6100 ± 50 K (with LB140 filter)
No chart, center of pattern box
Minolta color meter IIIF or equivalent
* Calibration method
Place the filter (LB140) against the pattern box. With the filter (LB140) in contact with the color temperature meter, adjust
the pattern box color temperature to 6100 ± 50 K.
LB140
Pattern BOX
(All white)
<Calibration method of pattern box>