Chapter 2 Troubleshooting
2.3 Level 2 FIP
2-10
2.3.4 Error Code FIP
FIP-1.1 Drum/toner cartridge (No cartridge, Cartridge error)
*:
Do not absolutely touch the powered parts, high-voltage output parts, and driving parts for check.
Procedure
Check
Action
YES
NO
1
- Initial check -
Are there errors such as use of parts in different
specifications, attachment error, damage,
transformation, dirt, or foreign object?
- Major check parts -
PWBA MCU XFABK(B) (PL9.1.25), Drum/toner
cartridge (PL10.1.2), HARNESS ASSY CRUM
(PL4.1.12)
Replace and
reattach the parts.
- There is a tool.
To step 2
- There is no tool.
To step 3
2
- HARNESS ASSY CRUM check -
Does the HARNESS ASSY CRUM function normally?
Select [SENSOR/SWITCH CHECK] on the
DIAGNOSTIC MODE MENU.
Replace the
PWBA MCU
XFABK(B)
Replace the
HARNESS ASSY
CRUM
3
- HARNESS ASSY CRUM check - *
Does the HARNESS ASSY CRUM connect normally?
Replace the
PWBA MCU
XFABK(B)
Replace the
HARNESS ASSY
CRUM
Summary of Contents for DocuPrint 2050
Page 1: ...DocuPrint 2050 Service Manual 1st Edition KON001CA ...
Page 3: ...Company Name Department Name Telephone No Full Name Employee No ...
Page 5: ...Preface ...
Page 11: ...Chapter 1 Service Call Procedure ...
Page 19: ...Chapter 2 Troubleshooting ...
Page 85: ...Chapter 3 Image Quality Troubleshooting ...
Page 114: ...Chapter 4 Disassembly Assembly and Adjustment ...
Page 193: ...Chapter 5 Parts List ...
Page 207: ...Chapter 6 General ...
Page 243: ...Chapter 7 Wiring Data ...
Page 247: ...Chapter 7 Wiring Data 7 1 Connector P plug J jack 7 4 ...
Page 252: ...Chapter 7 Wiring Data 7 3 Wiring Diagram between Parts 7 9 Continued from the preceding page ...
Page 264: ...Chapter 10 Machine Overview ...