Page 1: ...T S SPECIFICATIONS 1 OUTLINE AND DIMENSIONS 2 CIRCUIT DIAGRAM 5 ERROR CONTENTS 10 INDOOR P C BOARD CIRCUIT DIAGRAM 7 REFRIGERANT SYSTEM DIAGRAM 11 DISASSEMBLY ILLUSTRATION 12 PARTS LIST 19 Models Indo...

Page 2: ...12 2 12 5 HEATING 12 2 12 5 EER kW kW COOLING 2 42 2 42 2 03 2 03 HEATING 2 37 2 36 MOISTURE REMOVAL hr 7 5 AIR CIRCULATION Hi m3 hr 4 300 TYPE MFA 90NQN MFB 90NTN POWER SOURCE V 380 415 380 415 HI S...

Page 3: ...2 2003 12 15 Models RD 90EC RD 90TC OUTLINE AND DIMENSIONS 38 1 DRAIN PIPE LIQUID 12 7 FLARE GAS 28 58 FLANGE 1 550 MAXIMUM 1 450 600 450 713 MAXIMUM 25 4 SAFETY DRAIN Unit mm...

Page 4: ...3 2003 12 15 Models RO 90EPC RO 90TPB Unit mm...

Page 5: ...r more 10mm or more 200mm or more 500mm or more FRONT Height of side wall is free Height H of front wall is less than 1 200mm When total height of outdoor unit is lower than front wall add dimension h...

Page 6: ...5 2003 12 15 Model RD 90EC RO 90EPC CIRCUIT DIAGRAM...

Page 7: ...6 2003 12 15 Model RD 90TC RO 90TPB...

Page 8: ...POWER SUPPLY PCB EZ 0031HSE P UL1015 AWG16 WHITE UL1015 AWG16 BLACK TM102 TM101 240 220V 50Hz L N VA101 470V SA101 3600V F101 3 15A BET VA102 470V C102 0 22 LF101 ELF17N015A FH101 FH102 C103 0 01 C10...

Page 9: ...4 10K 1 10W R35 10K 1 10W R36 10K 1 10W 5V CN4 179844 1 C57 0 22 R85 120 1 2W K5 FTR F3A CN4 1 CN4 2 8 10 7 11 6 5 12 13 14 15 4 3 2 1 16 9 14V NC NC NC NC NC C48 0 01 F C7 0 01 F 5V 5V R3 4 7K 1 10W...

Page 10: ...10W R34 10K 1 10W R35 10K 1 10W R36 10K 1 10W 5V CN4 179844 1 C57 0 22 R85 120 1 2W K5 FTR F3A CN4 1 CN4 2 8 10 7 11 6 5 12 13 14 15 4 3 2 1 16 9 14V NC NC NC NC NC C48 0 01 F C7 0 01 F 5V 5V R3 4 7K...

Page 11: ...sor shortcircuited Outdoor heat exchanger temperature sensor open Outdoor heat exchanger temperature sensor shortcircuited Power source connection error Float switch operated Outdoor temperature senso...

Page 12: ...or Evaporator Flange Refrigerant Pipe 28 58 mm 1 1 8 Electronic Expansion Valve Charging Valve Strainer Flare Capillary Tube Flange Refrigerant Pipe 12 7 mm 1 2 Dryer CheckValve Pressure SW Accumulato...

Page 13: ...12 2003 12 15 Models RO 90EPC RO 90TPB 527 45 45 39 41 653 42 761 164 356 355 167 176 226 132 134 133 100 12 361 289 762 166 160 9 477 4 2 117 3 949 2 949 1 DISASSEMBLY ILLUSTRATION...

Page 14: ...Model RO 90EPC 13 2003 11 06 2...

Page 15: ...003 11 06 Model RO 90TPB 187 678 829 450 810 918 245 86 343 344 15 85 354 825 272 809 966 964 327 333 87 55 363 816 26 646 347 46 172 334 21 82 16 2 16 1 184 1 196 1 652 1 919 2 69 3 320 1 790 1 790 2...

Page 16: ...15 2003 11 06 Models RO 90EPC RO 90TPB 32 34 236 405 185 376 407 791 942 381 2 381 3 196 2 815 1 815 2 880 1 982 2 982 1...

Page 17: ...16 2003 11 06 Models RD 90EC RD 90TC 996 995 967 64 405 146 468 273 287 468 495 625 234 674 86 329 235 735 761 324 69 287 514 468 10 995 468 160 51 184 1 652 1 653 2...

Page 18: ...17 2003 11 06 Models RD 90EC RD 90TC 75 495 468 126 477 164 477 109 477 468 109 477 56 1 653 2 45 1 56 2...

Page 19: ...18 2003 11 06 Models RD 90EC RD 90TC 287 943 380 875 187 223 287 466 287 195 791 236 240 233 1 320 1 381 4 824 3 815 3 815 1 815 2 233 1 982 2 982 1 982 1 982 2...

Page 20: ...273 Rear Panel Assy 9364642000 9364642000 287 Cap Power 9352173011 9352173011 320 1 Wire Clamp Metal 313483219905 313483219905 324 Top Plate 9364634005 9364634005 INDOOR UNIT Ref No Description Ord Q...

Page 21: ...09 272 Strainer 9361931008 9361931008 289 Reinforcement Side Panel 9361704008 9361704008 320 1 Wire Clamp Metal 313483219905 313483219905 327 Suction Pipe A 9365599006 9365599006 333 Accumulator 93718...

Page 22: ...er S mall Remote control unit cord clamp S crew Use for air conditioner operation For connecting the piping Installation between flange joint and indoor unit For suspending the indoor unit from ceilin...

Page 23: ...0311G2403...