7.2  TP-A1-LM2 (Advanced keypad) 

 

7.2.1 

Keypad keys 

 

K

eypad “TP-A1-LM2” allows the user to run and stop the motor locally, monitor the running status, set the function 

code  data,  and  monitor  I/O  signal  states,  maintenance  information,  and  alarm  information.  Figure  8.5  shows  an 
overview of TP-A1-LM2. Table 8.3 explains the three main areas of the keypad. 

 

 

 
 

Figure 8.5: Names and Functions of Keypad Components 

Table 8.3: Keypad overview. 

Keypad item 

Specification 

Additional information 

LED indicators 

These indicators show the current running status of the 
inverter. 

Refer to Table 8.4. 

LCD monitor 

This monitor shows the following various information about the 
inverter according to the operation modes. 

 

Keys 

These keys are used to perform various inverter operations. 

Refer to Table 8.5. 

 

Table 8.4:  Indication of LED Indicators. 

LED Indicators 

Indication 

 

(Green) 

Shows the inverter running state. 

Flashing 

No run command input (Inverter stopped) 

ON 

Run command input 

 

(Yellow) 

Shows the warning state (light alarm). 

OFF 

No light alarm has occurred. 

Flashing /ON 

A light alarm has occurred. But inverter can continue running. 

 

(Red) 

Shows the alarm state (heavy alarm). 

OFF 

No heavy alarm has occurred. 

Flashing 

A heavy alarm has occurred. Inverter shuts off its output. 

 

Table 8.5: Overview of Keypad Functions. 

Keys 

Functions 

 

This key switches the operation modes between Running mode/Alarm mode and Programming mode. 

 

Reset key which works as follows according to the operation modes. 

 In Running mode: 

This key cancels the screen transition. 

 In Programming mode: This key discards the settings being configured and cancels the screen transition. 

 In Alarm mode: 

This key resets the alarm states and switches to Programming mode. 

 / 

 

UP/DOWN key which works as follows according to the operation modes. 

 In Running mode: 

These keys switch to the digital reference speed (when local mode). 

 In Programming mode: These keys select menu items, change data, and scroll the screen. 

 In Alarm mode: 

These keys display multiple alarms and alarm history. 

 / 

 

These keys move the cursor to the digit of data to be modified, shift the setting item, and switch the screen. 

Program key 

STOP key 

Run key

 

(forward) 

LED indicators 

Run key (reverse) 

RESET key 

LCD monitor 

Programming keys 

HELP key 

SET key 

UP/DOWN/LEFT/RIGHT arrow key 

Summary of Contents for FRENIC-Lift FRN0010LM2C-4E

Page 1: ...Starting Guide Dedicated inverter for lift applications with induction motor in open loop 3 ph 400 VAC 4 0 15 kW SG_LM2C_EN_1 0 0...

Page 2: ...Page 2 of 28 Fuji Electric Europe GmbH Version Changes applied Date Written Checked Approved 1 0 0 First release 25 10 2019 J Alonso 1 0 1 Small text corrections 25 11 2019 J Alonso C Arjona J Catal...

Page 3: ...re configuration 13 7 Keypad operation 14 7 1 TP E1U Basic keypad 14 7 1 1 Led monitor keys and LED indicators on the keypad 14 7 1 2 Overview of operation modes 15 7 1 3 USB connectivity 15 7 1 4 TP...

Page 4: ...s bodily injuries Failure to heed the information indicated by this symbol may lead to dangerous conditions possibly resulting in minor or light bodily injuries and or substantial property damage Fail...

Page 5: ...parts in the main circuit their insulation coat may break for any reasons In such a case ensure the signal control wire is protected from making contact with any high voltage cables Doing so could ca...

Page 6: ...es that they comply with the essential requirements of the Electromagnetic Compatibility EMC Directive 2014 30 EU and the Low Voltage Directive 2014 35 EU issued by the Council of the European Communi...

Page 7: ...13849 1 PL e EN60204 1 stop category 0 EN61800 5 2 STO SIL3 EN62061 SIL3 Low Voltage Directive EN61800 5 1 Over voltage category 3 EMC Directive with external EMC filter EN12015 EN12016 EN 61800 3 A1...

Page 8: ...0 195 0 FRN0015LM2C 4E FRN0019LM2C 4E FRN0025LM2C 4E FRN0032LM2C 4E 2 160 0 360 0 195 0 FRN0010LM2C 4E to FRN0025LM2C 4E FRN0032LM2C 4E 4 Removal and attachment of front cover In order to remove prop...

Page 9: ...ed in table 5 1 Table 5 1 Power terminals description Terminal label Description of the power terminals L1 R L2 S L3 T 3 phase supply input from mains supply U V W 3 phase motor connection for inducti...

Page 10: ...C07 1 0 0 L15 4 100 Intermediate speed 2 C08 1 0 1 L16 5 101 Intermediate speed 3 C09 1 1 0 L17 6 110 Intermediate speed 4 C10 1 1 1 L18 7 111 High speed 1 C11 In case that lift controller signals doe...

Page 11: ...proper usage of EN terminals is recommended In figure 5 6 an example of wiring is shown Terminal Function description of the digital inputs FWD Clockwise rotation of the motor seen from the shaft sid...

Page 12: ...tact rating 250 VAC 0 5 A 30 VDC 0 5A Y4A Y4C Main MC control function SW52 2 Contact rating 250 VAC 0 5 A 30 VDC 0 5A Y3A Y3C Speed detected function FDT Contact rating 250 VAC 0 5 A 30 VDC 0 5A 5 4...

Page 13: ...d NPN SINK SOUCE SW2 Terminating resistor of RS 485 communications port 1 Port 1 is in RJ 45 connector When keypad or converter for FRENIC Loader is used set SW2 to OFF position When DCP or Modbus com...

Page 14: ...want to do in each mode as follows In Running mode Pressing this key switches the information to be displayed Monitor data fixed on E52 In Programming mode Pressing this key displays the function cod...

Page 15: ...rm has occurred Running mode Monitor of running status Power ON Release of a heavy alarm Figure 8 2 Status Transition between Operation Modes Simultaneous keying Simultaneous keying means pressing two...

Page 16: ...Maintenance Information 5 CHE Display maintenance information including cumulative run time Cumulative RUN time 5_00 DC link bus voltage 5_01 Max temperature inside the inverter 5_02 Number of startu...

Page 17: ...alarm has occurred Flashing ON A light alarm has occurred But inverter can continue running Red Shows the alarm state heavy alarm OFF No heavy alarm has occurred Flashing A heavy alarm has occurred In...

Page 18: ...firmation of function code settings 3 Confirm revised data PRG 2 3 Allows confirmation of function code changes from factory default settings 4 Copy data PRG 2 4 Reads writes and verifies function cod...

Page 19: ...lect a target menu item by using keys Then press key Adjust data value by using keys Then press key to store data into memory Inverter memorizes changed data and moves next screen automatically Invert...

Page 20: ...as to be performed Auto tuning will get special data from the motor like no load current P06 stator resistance P07 stator inductance P08 and slip frequency P12 In order to perform an auto tuning follo...

Page 21: ...s and S curves are used we have to enter in Table 10 1 from the left hand column in the row of the speed that is settled before the change ex C08 and look up in the column pointing at the target speed...

Page 22: ...of brake control will be activated and the mechanical brake opens releases after t2 time elapses delay time to the reaction of contactors coil After completion of time F24 the speed set point will be...

Page 23: ...oad than with half load it means that the slip is not enough We need to give more slip when the cabin is empty with more slip the lift will go faster than without load in driving condition in this cas...

Page 24: ...20 s Increase F24 Max F24 1 5 s Too high torque Reduce P06 P06 30 70 of P03 Not related to inverters setting Check brake operation Check guides oil alignment etc Check car fixation shoes TROUBLESHOOT...

Page 25: ...rake reaction too soft Increase F21 Max F21 90 Check F22 0 00s Insufficient torque Increase P06 P06 30 70 of P03 Increase F09 Max F09 5 0 Not related to inverters setting Check security chain operatio...

Page 26: ...fective Ambient temperature too high OH2 External Alarm Digital input programmed with value 9 THR is not active OH3 Inverter internal overheat Check temperature inside electrical cabinet OH4 Motor pro...

Page 27: ...communication error CAN bus disconnected from the inverter Electrical noise connect cable shield Terminating resistor not connected bbE Brake status monitoring according to EN81 20 Brake state differ...

Page 28: ...4 Fax 33 4 74 90 91 75 info france fujielectric europe com www fujielectric europe com United Kingdom Fuji Electric Europe GmbH UK Branch Bedford i Lab Stannard Way Priory Business Park Bedford MK44 3...

Reviews: