48
Comp. Value Setting
What is "Comp. Value Setting"?
It allows you to set each of set load arrival output, high limit judgment value, and low limit
judgment value.
OF
value is a set load arrival output,
HI
is a high limit judgment value, and
LO
is a low
limit judgment value.
When the measured value is smaller than LO value, it is judged LO. When LO value
≤
measured value
≤ HI value, it is judged GO.
When HI value is smaller than the measured value, it is judged HI, and each output is
made from the external input/output terminal.
A set load arrival output is made when OF value is smaller than the measured value
separately from the high or low limit judgment.
How to set
1. Press MENU key.
2. Use
⋀
⋁
key to select
Comparison Setting
.
3. Press SET key.
4. Use
⋀
⋁
key to select
Comp. Value Setting
.
5. Press SET key.
6. Set OF.
7. Use
<
>
key to change the digit and
⋀
⋁
key to change the value. (default: 1000)
8. Press SET key to determine the value of
OF
and set
HI
.
9. Use
<
>
key to change the digit and
⋀
⋁
key to change the value. (default: 1000)
10. Press SET key to determine the value of
HI
and set
LO
.
11. Use
<
>
key to change the digit and
⋀
⋁
key to change the value. (default: 100)
12. Press SET key to determine the value of
LO
and confirm all values have turned
green.
13. Press SET key again to complete this operation.