1) If water collects in the filter (built into the reducing valve), drain it off right away.

2) Apply grease to the press ram rotation stopper every month.

3) Periodically check for loose terminals on the machines.

Contact telephone for user support (Engineering division): 81-3-3265-5437 (only in Japanese)

Or, ask questions by e-mail please. E-mail:[email protected]

Please make sure to check the model name and serial number before calling.

Model No,

Parts

FCP-100

FCP-200

FCP-500

FCP-750H

FCP-1000

Suppliers

Quick Exhaust Valve

AQ400-03

SMC

Speed Controoller

AS2201F-02-08S

AS4000-02

AS4000-03

AS4000-03

AS4000-02

SMC

Sorenoid Valve

VF1120-1GC-01

VP342-1G-01

VT325-021G

VT325-021G

VS4120-021

SMC

Filtre & Regulatr

AW20-02G

AW20-02G

AW30-02G

AW30-02G

AW30-02G

SMC

WS3400

WS3400

Matsushita Denko

Switch

ZAP-G

ZAP-G

ZAP-G

OMRON

Inching Valve

A

(

1/4

)

A

(

1/4

)

A

(

3/8

)

A

(

1/4

)

KITZ

Silencer

AN120-M5

2510-002

2510-002

2510-002

2510-003

2510-002

×

2

SMC

For your information

Company name

URL

Matsushita Denko

http://www.mew.co.jp/ac/e/index.jsp

OMRON

http://www.omron.com/index2.html

SMC

http://www.smcworld.com/2002/index3_e.htm

KITZ

http://www.kitz.co.jp/english/index.html

Summary of Contents for FCP-100

Page 1: ...1000 Ver 3 01 Make sure to read this manual before using this press Then store it in a safe location The specifications may be changed without prior notice FUJI CONTROLS CO LTD 1 5 6 Iidabashi Chiyod...

Page 2: ...ill be using the machine outside Japan make sure to follow the safety regulations in the country where the press will be used GENERAL WARNING Pneumatic presses are dangerous machines if not handled ca...

Page 3: ...the press Especially when matching mold parts or when more than one worker is involved in press preparations he she may be injured Never touch the mechanical stopper jig metal die rotation stopper ar...

Page 4: ...supply inlet Instruction manual CAUTION If you sell or loan the press to someone else make sure to give them this instruction manual Modifications disassembly WARNING Never modify disassemble or repai...

Page 5: ...n Method 3 2 Preparation 3 Adjustment of each section 3 1 Mold Matching inching operation 3 2 Stroke Adjustment 4 Options 4 Maintenance 5 Spare parts 5 Wiring diagram 6 Diagrams of Air circuit 6 Speci...

Page 6: ...uick exhaust valve This valve increases the exhaust capacity of air This unit is installed only on the FCP 750H Acrylic safety cover A safety cover used to keep body parts from getting caught between...

Page 7: ...filter and regulator Dirty water may splash out when opened Put a cup under the drain to catch the water when you open it Two handed pushbutton switches Both switches must be pressed at the same time...

Page 8: ...air line The available air pressure should be from 0 2 to 0 5 MPa Adjust the air pressure using a regulator to achieve the required output for the press See page 10 Press output chart 3 Then connect t...

Page 9: ...revent the press from hitting bottom if no workpiece is present 2 Set the press fit dimension thickness of a workpiece by adjusting the press stroke 3 Adjust the Press Output and Lowering Speed 1 The...

Page 10: ...FCP 750H FCP 1000 Suppliers QuickExhaust Valve AQ400 03 SMC SpeedControoller AS2201F 02 08S AS4000 02 AS4000 03 AS4000 03 AS4000 02 SMC Sorenoid Valve VF1120 1GC 01 VP342 1G 01 VT325 021G VT325 021G...

Page 11: ...i le nce r FCP 100 FCP 200 and FCP 500 The air tank is not installed on the FCP 200 Pushbutton Switch Pushbutton Switch Solenoid Valve Plug Terminal Block Solenoid Valve Two handed Pushbutton Switches...

Page 12: ...hing Val ve Fi lter Reg ulat r A ir O utle t Sile ncer Spee d Co ntro ller Sol enoi d Va lve Solenoid Valve Silencer Air tank Filter Regulatr Air Outlet Inching Valve Speed Controller Quick Exhaust Va...

Page 13: ...200 235 280 285 285 L mm 245 280 300 305 305 M mm 25 50 25 50 25 50 25 60 25 50 N mm 125 140 145 200 200 O mm 150 170 180 230 230 P mm 420 420 450 450 450 a mm 15 H9 15 H9 15 H9 20 H9 20 H9 b mm 25 28...

Page 14: ...rent Power of Solenoid Valve unit VA FCP 100 FCP 200 FCP 500 FCP 750H FCP 1000 In rush 6 6 75 75 100 Holding 4 4 27 27 20 3 Air Consumption unit NI FCP 100 FCP 200 FCP 500 FCP 750H FCP 1000 1 4 1 5 3...

Page 15: ...10 0 0 0 0 4 0 Press output Press output Press output Press output Supplied air pressnre Supplied air pressnre Press output Supplied air pressnre Supplied air pressnre Supplied air pressnre...

Reviews: