71130/11E/0318
Command RT
<id>RT<para7>
Used to set the real-time clock of the WEATHER STATION (Real Time).
Access:
Configuration mode (ADMIN).
Description:
Output and setting of time and date of WEATHER STATION.
Parameter description:
0:
Synchronization of date and time deactivated by GPS information.
1:
Synchronizes seconds acc. to GPS every day at 3:30:30h.
2:
Synchronizes seconds and minutes by GPS every day at 3:30:30h.
3:
Synchronizes time and date by GPS every day at 3:30:30h.
T:
System time of WEATHER STATION output in the format: "
hh:mm:ss
".
Example for setting the system time to 12 noon: "00RTT120000"
D:
System date of WEATHER STATION output in the format: "
dd:mm:yy
".
Example for setting the date to 25.09.2012: "00RTD250912"
G:
One-off setting of the time and date acc. to GPS information (optional).
Time and date are set automatically if a valid GPS time is received (see also
Command "TZ" Time Zone).
S:
Minutes and seconds synchronised to GPS time.
Time and date are set automatically if a valid GPS time is received.
Command SH
<id>SH<para5>
Station height to calculate the air pressure at standard elevation zero (NHN).
Access:
Configuration mode (ADMIN).
Description:
Input of the station height in meters above sea level for conversion of the air pressure
to sea level.
For an automatic setting of the station height see parameter “HS“.
Parameter description:
0...9000: Station height in meters (basis for conversion of the
air pressure to sea level).
Value range:
0
Command SM
<id>SM<para5>
Energy saving mode (Sleep Mode).
Access:
Configuration mode (ADMIN).
Description:
Entry of the alarm interval for measurement and telegram output.
The Weather station is called up by the RTC in a specified interval, measures once,
and outputs afterwards the current measuring values via the set telegram.
The heating is deactivated for the sleep mode, and the averaging „AV“ is switched off,
in order to receive actual measuring values.
Normally the analog data outputs will be switched off at entry of sleep mode.
However the analog outputs can be reactivated by the command AO=2.
Important:
Even at running sleep mode the daily total and intensity of precipitation
will be kept and actualized.
Parameter description:
0
:
Energy saving mode off.
1...600:
Alarm interval in seconds.
Initial value:
0