52 - 70
71130/11E/0318
Command PT
<id>PT<para5>
Precipitation-intensity-threshold for the precipitation status flag.
Access:
Configuration mode (ADMIN).
Description:
Sets the threshold of the precipitation intensity in µm, when
the status flag is set to “1”.
In addition, the status flag can be linked to a precipitation event counter. This threshold
is required for the precipitation start detection for ex. with drizzle (see also command
PE).
Parameter description:
1..200 Threshold of intensity in µm/h. The status flag is set at this threshold or
by the event counter.
Initial value:
10
Command PW
<id>PW<para5>
Dimension of time frame (Precipitation Window) for starting conditions of precipitation.
Access:
Configuration mode (ADMIN).
Description:
Time frame in seconds for number of drops or parts, which have to be acquired,
before precipitation is signaled, see
command PE
.
Value range:
10..60 [s]
Initial value:
60
Command RD
<id>RD<para5>
Delayed response (Response Delay).
Access:
Configuration mode (ADMIN).
Description:
The response of the WEATHER STATION is delayed by the time specified in ms with a
command via the serial interface.
The minimum delay time from the end of the last character of the request telegram until
transmission of the first character of the response telegram is 5ms.
For the half duplex mode we recommend RD=20 in order to guarantee a smooth
communication with diverse interface converters.
Value range:
5...1000 [ms]
Initial value:
5
Command RS
<id>RS<para5>
Warm-boot WEATHER STATION (Reset).
Access:
Configuration mode (ADMIN).
Description:
The WEATHER STATION is restarted on transmission of this command.
Parameter description:
1:
The WEATHER STATION performs a warm boot, behaving as if the supply
voltage had just been connected.
2:
Resets the precipitation sum.
Value range:
1..2