ba_7-1-120/11E/0318
6.2.13 Command TR
<id>TR<parameter><CR>
Telegram output
Access:
Read / write.
Description:
This command initiates one-off transmission of a telegram. The
parameter specifies the type of telegram.
Parameter description:
1
Measured value telegram.
2
Sensor data telegram.
Response telegram:
See
section
Fehler! Verweisquelle konnte nicht gefunden werden.
Value range:
1...2
Initial value:
-
6.2.14 Command TT
<id>TT <parameter><CR>
Automatic telegram output
Access:
Read / write.
Description:
The command TT is used to select the automatic output of telegrams
(interval = 1 second).
Automatic telegram output remains switched off for the first 10
seconds after start-up of the Weather Station
. During this time the
user has the opportunity of changing the parameter TT.
Parameter description:
0
Automatic telegram output switched off.
1
Measured value telegram.
2
Sensor data telegram.
Response telegram:
See
section
Fehler! Verweisquelle konnte nicht gefunden werden.
Value range:
0...2
Initial value: