25 / 34
ba_7-1-120/11E/0318
6.2.9 Command LC
<id>LC<parameter><CR>
LED control
Access:
Read / write.
Description:
The command LC is used to specify the mode for control of the blue
LED.
Parameter description:
Parameter
Description
0
LED (blue) indicates wind speed
1
LED (blue) is dark
Examples:
LED dark blue:
"00LC1\r"
LED blue indicates wind speed:
"00LC0\r"
Value range:
0 / 1
Initial value:
0
6.2.10 Command RS
<id>RS<parameter><CR>
Reset
Access:
Read / write.
Description:
Through the command RS a reset of the microcontroller is carried out.
The cause for the last reset is output without stating a parameter.
Here, the output occurs in the form of strings (see the following table),
which are lined up in a row, separated by spaces.
String
Description
PORF
Power On Reset Flag.
EXTRF
External Reset Flag.
BORF
Brownout Reset Flag.
WDRF
Watchdog Reset Flag.
PDIRF
Programming/Debug Interface Reset Flag.
SRF
Software Reset Flag.
SDRF
Spike Detector Reset Flag.
Parameter description:
1
Watchdog reset
2
Software reset
Value range:
1 / 2
Initial value:
-