LIST OF FAULTS
Message
fault
Fault condition
Possible cause
Actions
Motor fault
Step by step
04M1
Loss of entry:
% IX.1.00.05
Absence_Alarm_
Motor_04m1
Motor overload
Excessive engine
temperature
Engine overspeed
Pulse control error
Overvoltage protection
Undervoltage
Refer to the drive
technical
documentation to
analyze the cause of
the fault and remedy it
Acknowledge the fault
on the "Fault History"
page
Bath level
detection
fault
During the level
detection phase,
lowering into slow
speed, the race
was reached
without level
detection
Problem with the electrical
connection of the
detection system. 05B2-
05KA2
Incorrect values of
parameters or program
Check the operation
of the level detection
using the "Manual
Mode" page
Check the values of
the parameters and
the selected program
Acknowledge the fault
on the "Fault History"
page
Faulty
maximum
lowering stop
Position> 40mm below
the detected bath level
Incorrect parameters or program
values
Check the values of
the parameters and
the selected program
Acknowledge the fault
on the "Fault History"
page