ES08
‐
15
Controller
v1.01.05
2022
‐
02
‐
03
FS
‐
Curtis
Page
27
Symbol
or Field
Name Description
Password
To View
Password
To Edit
Run Time
Remaining
Running hours until next scheduled
maintenance.
User Service
Elapsed Time
Remaining
Elapsed hours until next scheduled
maintenance.
User Service
Timer Reset
Button
AFTER completing the relevant maintenance
task(s) as described in the Instruction
Manual, press and hold for two seconds to
reset both the run time remaining and
elapsed time remaining values.
User Service
Previous Screen
Press to go back to the previous screen,
which is usually the maintenance status
screen.
User n/a
Next Screen
Press to go forward to the next screen,
which is limited to moving between the air-
end, tip seal and bearing grease
maintenance screens.
User n/a
The set values for the run time and elapsed time maintenance intervals for each of the component
maintenance screens are listed in Table 2.10. Please refer to the Instruction Manual for detailed guidance
about the maintenance procedures.
Table 2.10 – Run Time and Elapsed Time Maintenance Interval Settings
Component
Run Time Maintenance Interval
(hours)
Elapsed Time Maintenance Interval
(hours)
Motor 20,000
70,080
V-Belt 2,500
8,760
Air-End 20,000
70,080
Tip Seal
10,000
35,040
Bearing Grease
10,000
35,040
Air Filter
2,500
8,760
High Pressure Hose
10,000
35,040
Check Valve
5,000
17,520
Safety Valve
2,500
8,760
Note: