ES08
‐
15
Controller
v1.01.05
2022
‐
02
‐
03
FS
‐
Curtis
Page
17
Parameter
Set Value
Function
Password
To View
Password
To Edit
#1 Main Motor
Starts Reset
#2 Main Motor
Starts Reset
#3 Main Motor
Starts Reset
[ES11 & ES15]
#4 Main Motor
Starts Reset
[ES15]
Push and hold the slider to
the right-hand side for
2 seconds to reset the
cumulative motor start
counter to zero. The slide will
temporarily appear green in
colour to acknowledge the
command.
The slider automatically
resets to the left-hand side
and appears all-grey in colour
after use.
For use as required to reset
the cumulative motor start
counter to zero. Check the
equipment status display
screen for confirmation of
this action.
User Service
Remote Control
Single Contact is the
standard setting.
Double Contact is the
alternate setting.
Specifies the type of hard-
wired remote control
switch(es) and switching
logic.
User Service
Rotation
Interval
48 hours
The interval in running hours
between the starting
sequence being cycled so as
to maintain equal run time
across all the modules.
User Service
Warning:
The compressor set’s built-in auto restart function allows it to be switched on automatically after a
power supply interruption has been rectified. This feature does not include provision for any alarm or
annunciation that the unit is about to start. The auto restart function should therefore NOT be used unless
the person conducting a business or undertaking involving the management or control of the plant has first
implemented at least the following risk control recommendations:
a) Do not operate the compressor with any of its maintenance access panels open or removed.
b) Before opening or removing any of its maintenance access panels or performing any maintenance
work on the compressor or connected pneumatic system: Switch off the unit; isolate and tag-out the
power supply; carefully release the residual air pressure from the internal piping and any external air
receiver tank and connected piping; and close the air outlet valve.