FSA GT1-70 Quick Start Manual Download Page 9

 
 
 
 
 
2. Faulty Shut Off 
Valve 
 
 
3. Still Filling 
 
 
4. Low 
Pressure/Blockage 

shift the air pockets. You can also tap on the 4-way shut off 
valve (the cube shape fitting on the back) to try and clear the 
air pocket. If this fails, turn the water off, bleed out the 
pressure then turn the incoming water back on to try and clear 
it. 
2. If it is not an air lock, there may be something wrong with 
the shut off valve. These parts are warranted for 2 years from 
date of purchase. Outside this time, it is recommended to 
replace them. 
3. Ensure that you have allowed the system enough time to 
replenish the tank. Check with other household members to 
see if someone recently drew water from the unit. 
4. Low pressure can cause the water to continuously run to 
waste without producing filtered water. Ensure your feed water 
pressure is > 25psi. Your pre-filters may also be blocked. 

Additional Extras 

I. Water Hammer Arrester 

Sioux Chief shock arresters are designed for use in hydraulic hammer arresting 
applications. They are built to reduce or eliminate hydraulic shock, otherwise known as 
water hammer. They do this by absorbing pressure surges within water or other fluids 
that are suddenly stopped or forced in other directions by fast closing valves. Sioux 
Chief shock arresters are best used at the point of shock and should be installed as 
close to the valve or piping where the shock originates from. Sioux Chief shock 
arresters are designed with the latest diaphragm technology. A high-grade diaphragm 
is sealed inside the vessel creating a barrier between fluid and air chambers. The air 
chamber acts as a cushion which compresses when system pressure suddenly 
increases or surges as a result of hydraulic shock. 

The water hammer arrestor is installed either at your washing machine or your 
dishwasher inlet. 

II. Leak Shut Off Kit 

Highly absorbent capsule sits in place under the shut off lever (like a reverse 
mouse trap). 
It quickly absorbs water causing the capsule to expand in an upward 
direction putting pressure on the shut off valve. When sufficient water has 
been absorbed, the lever will snap shut, stopping the inlet water flow and 
saving any possible water damage. (Plastic outer cover needs to be 
REMOVED). 

The Shut off valve should be connected between the FWV and the Filter 
System inlet. 

This system is certified to WaterMark Standards AS/NZS 3497 Under Certificate number 23247. 
WaterMark certification is the level of certification required by law for a qualified plumber in 
Australia to install a water filter system. 

 

Summary of Contents for GT1-70

Page 1: ...ter Connection 3 II Drain Clamp 3 III Drilling Faucet Hole Stainless Steel Sink 3 IV Mounting the Faucet 4 V Storage Tank Assembly 4 VI Assembling the System 5 Connecting the RO System 5 I Tubing 5 Sy...

Page 2: ...ssure 175 kPa 700 kPa Temperature 4 5 C 38 C pH Level 2 11 TDS 0 mg L 2 000 mg L Iron 0 mg L 0 3 mg L Manganese 0 mg L 0 1 mg L Hardness 0 mg L 200 mg L III Space Requirements System Dimensions Height...

Page 3: ...tween DO NOT apply thread tape to these connections as they are designed to use the washers only Thread tape is only required on the male thread of the FWA if it is not installing to a flex line With...

Page 4: ...tance thread the Compression nut over the tubing followed by the cone washer Then firmly press the gasket into the end of the tubing You can then insert the tubing into the base of the faucet and secu...

Page 5: ...t the faucet due to the low flow rate of the membrane The drain line however should begin to run as soon as water reaches the membrane 5 When the water first comes out of the tap it will be grey and d...

Page 6: ...e first 45 seconds of water If the system has been shut down for over 1 week discard a full tank of water Maintenance I Replacement Parts Filtration tubing should be replaced periodically about every...

Page 7: ...Water Quality 1 Turn on the water supply and ensure there are no obstructions to the water flow 2 Disconnect the tube between the membrane and pre filters and run water at full pressure to see if wate...

Page 8: ...of the water especially when new If you have low TDS water already it is possible for the TDS level out of the alkaline filter to be higher than your inlet water This is because you are adding mineral...

Page 9: ...suddenly stopped or forced in other directions by fast closing valves Sioux Chief shock arresters are best used at the point of shock and should be installed as close to the valve or piping where the...

Page 10: ...stems must be installed by a qualified plumber The consumer is responsible for keeping record and proof of installation in the form of an invoice and or receipt Filter systems must be maintained as pe...

Page 11: ...to terms and conditions outlined below This extended warranty covers the below parts of the system GT8 0S Twin O Ring Housings GT8 31 Reverse Osmosis Housing GT35 12 NPT Stainless Steel Centre Joiner...

Reviews: