FSA GT1-26-4 Manual Download Page 8

Troubleshooting 

Problem 

Possible Cause(s) 

Solution 

Leaking between 
fitting & tubing 

Unseated Tube 

Check all tubing connections by firmly pushing them into the 
fitting. Check that there are no kinks or any obvious issues. If 
the problem persists, remove the tubing and check for a clean 
cut with no burs. Push the tubing back in and try again. If this 
does not work please contact customer support. 

Leaking from 
Feed Water Valve 

1. Damaged or 
Missing Washer 
 
 
2. Not Tight 
Enough 
 
 
 
 
 
 
3. Thread is too 
Short 

1. Check the valve to see if the washer is inside, if it is 
damaged it may need replacing – this is a common size 
washer and can be purchased from most hardware/plumbing 
stores. 
2. If the diverter valve is loose (or you can easily swivel the 
fitting without resistance, the fitting is not tightened enough. It 
may feel like you can’t tighten it anymore and it just keeps 
spinning but if you use a gripping tool (multi grips) to grab the 
collar of the fitting and use your hand to hold the valve itself 
steady, you will be able to further tighten the valve. The valve 
is tight enough when you feel light to moderate resistance 
when trying to swivel the valve. 
3. If you screw the valve on and the collar ‘bottom’s out’ on the 
tap, you may need to add another washer (to bulk up the 
space). 

The unit is not 
producing any 
water? 

1. Water Supply is 
off or 
disconnected. 
 
2. Pre-Filter has a 
blockage 
 
3. Insufficient 
Water Pressure 
 
4. Water Quality 

1. Turn on the water supply and ensure there are no 
obstructions to the water flow. 
2. Disconnect the tube between the membrane and pre-filters 
and run water at full pressure to see if water comes out of the 
filter. – If the water does not come out (or is very weak 
pressure) the filter may need to be changed. 
3. Reverse Osmosis required 50psi (Minimum) to operate – 
70psi+ is ideal. If you have lower than 50psi pressure this unit 
may not be suitable for you. 
4. Ensure that the water quality meets the feed water 
requirements outlined previously. High levels of impurity such 
as hardness and salt can cause the system to block or not 
produce water. 

I am getting much 
more waste water 
than filtered water 

1. Water Pressure 
 
 
 
2. Water Quality 
 
 
3. Blockage 

1. Our units are designed to run at approx. 1:1 – 1:2 waste 
water ratio at 70 psi. If your pressure is lower than 70 psi, the 
production rate may decrease and cause more drain water 
than filtered water. 
2. If your inlet water quality is poor and contains higher salts 
and hardness the filter may produce less water than the 
specified amount. 
3. If you have good pressure, and average water quality it is 
possible there is a small blockage somewhere in the system. 
Try to follow the water flow along the system, disconnecting 1 
tube at a time to try and pinpoint where the water is ‘stopping’ 

High pH Reading 

1. Alkaline Filter 
    (If Applicable) 
 
2. GAC Filter 
 
 
 
 
3. Insufficient 
Testing Equipment 

1. Alkaline Filters are designed to increase the pH of the water. 
When the filter is new it will be high but will soon settle to the 
advertised levels after adequate flushing. 
2. If you have a post GAC filter (Carbon), this will naturally 
increase the pH of the water. pH is the measure of Hydrogen 
in the water and this hydrogen will vent off the water if you 
leave it to stand and the pH will then drop back down to the 
normal level. 
3. pH testing equipment can range from a cheap test pen right 
up to lab grade equipment. Before coming to a conclusion on 
pH issues, it is best to ensure the equipment used to measure 
the pH of the RO water is of high standards and suitable for 
reading pH levels in low EC water (i.e. The guy at the pool 
shop is not going to cut it). We have access to high quality 

Summary of Contents for GT1-26-4

Page 1: ...3 II Drain Clamp 3 III Drilling Faucet Hole Stainless Steel Sink 3 IV Mounting the Faucet 4 V Storage Tank Assembly 4 VI Assembling the System Photos Below 5 Connecting the RO System 6 I Tubing 6 Sys...

Page 2: ...350 kPa 700 kPa Temperature 4 5 C 38 C pH Level 2 11 TDS 0 mg L 2 000 mg L Iron 0 mg L 0 3 mg L Manganese 0 mg L 0 1 mg L Hardness 0 mg L 200 mg L III Space Requirements System Dimensions 4 Stage Hei...

Page 3: ...tween DO NOT apply thread tape to these connections as they are designed to use the washers only Thread tape is only required on the male thread of the FWA if it is not installing to a flex line With...

Page 4: ...tance thread the Compression nut over the tubing followed by the cone washer Then firmly press the gasket into the end of the tubing You can then insert the tubing into the base of the faucet and secu...

Page 5: ...al cartridges maintain minimal contact with the surface of the carbon filter handle by the end caps only to avoid contamination 5 Screw up the housings while they are in a vertical position to ensure...

Page 6: ...he water it gives the water a milky appearance This will eventually dissipate as the air is flushed from the system this can sometimes take a few days to stop completely The water is still safe to dri...

Page 7: ...ing the Pressure Limiting Valve every 2 years If the system is having issues with the shut off valve and is over 2 years old the 4 way shut off valve should also be replaced II Replacement Cartridges...

Page 8: ...e changed 3 Reverse Osmosis required 50psi Minimum to operate 70psi is ideal If you have lower than 50psi pressure this unit may not be suitable for you 4 Ensure that the water quality meets the feed...

Page 9: ...mmendations it is likely that the increased TDS is due to the filters needing replacing 4 This is common as sometimes the lines may be mixed up Make sure that the tubing connected to the Drain Line fl...

Page 10: ...of shock and should be installed as close to the valve or piping where the shock originates from Sioux Chief shock arresters are designed with the latest diaphragm technology A high grade diaphragm i...

Page 11: ...stems must be installed by a qualified plumber The consumer is responsible for keeping record and proof of installation in the form of an invoice and or receipt Filter systems must be maintained as pe...

Page 12: ...to terms and conditions outlined below This extended warranty covers the below parts of the system GT8 0S Twin O Ring Housings GT8 31 Reverse Osmosis Housing GT35 12 NPT Stainless Steel Centre Joiner...

Page 13: ......

Reviews: