9.2.5.4. Monitoring Data of SDH Regeneration Segment Shown As NA
Here are the situations when the monitoring data of the SDH regeneration segment for the port is shown as NA:
(1) When optical module is not inserted into the port, the optical module is not in position but the port is
enabled.
(2) The port and the module are normal and the port is enabled.
(3) Optical module is inserted into the port but it is mismatched and the port is enabled.
At this time, all the data will be shown as NA. The suspicious interval marker is trustworthy (after 900/86400
seconds) or untrustworthy. The running time is normal and counts from 0, as shown in the figure below:
Figure9-51 Optical Module of SDH Regeneration Segment Not In Position
Here are the situations when the monitoring data for the board is shown as NA:
(1) When the board is not in position or is pre-configured with an empty slot and the port for the board is
enabled, all the data will be shown as NA.The suspicious interval is marked as untrustworthy, and the running
time is always 0 without any change, as shown in Figure 2.5-7:
Figure9-52 SDH Regeneration Segment Monitoring Data
(2) When the board is mismatched and the port for the board is enabled, all the data will be shown as NA. The
suspicious interval is marked as untrustworthy, and the running time counts from 0 without any change, as
shown in Figure 2.5-8:
Summary of Contents for M6500 Series
Page 12: ...M6500 Series NE Configuration Manual 11 Figure 1 3 Start NMS Server...
Page 109: ...M6500 Series NE Configuration Manual 108 Figure6 5 TP Multiplexing Configuration Step 2...
Page 113: ...M6500 Series NE Configuration Manual 112 Figure6 12 Set Line Side PM Overhead...
Page 116: ...M6500 Series NE Configuration Manual 115 Figure6 16 Configure Line Side Port TTI...
Page 117: ...M6500 Series NE Configuration Manual 116 Figure6 17 Configure Client Side Local End Port TTI...
Page 129: ...M6500 Series NE Configuration Manual 128 Figure7 10 Select Protection Mode...