FRYMASTER FPD65 SERIES GAS FRYERS
CHAPTER 2: IMPORTANT INFORMATION
2-4
2.5 Pre-Installation (cont.)
B.
Clearances
: The fryer area must be kept free and clear of all combustibles. This unit is design-
certified for the following installations:
1.
Commercial installation only (not for household use).
2.
Non-combustible floor installation equipped with factory-supplied 6-inch (15-cm) adjustable
legs or 5-inch (13-cm) casters;
3.
Combustible construction with a minimum clearance of 6-inches (15-cm) side and 6-inches
(15-cm) rear, and equipped with factory-supplied 5-inch (13-cm) casters.
C.
Installation Standards
1. U.S. installations must meet:
2. Canadian installations must meet:
American National Standard Institute
CAN 1-B149 Installation Codes
ANSI Z83.11
Canadian Gas Association
American Gas Association
55 Scarsdale Road
8501 E. Pleasant Valley Road
Don Mills, ONT, M3B 2R3
Cleveland, OH 44131
National Electrical Code
Canadian Electric Code c22.1, part 1
ANSI/NFPA #70
Canadian Standards Association
American National Standard Institute
178 Rexdale Blvd.
1430 Broadway
Rexdale, ONT, M9W 1R3
New York, NY 10018
NFPA Standards #96 and #211
National Fire Protection Association
470 Atlantic Avenue
Boston, MA 02110