Tube Power Boost

®

Owner’s Manual 

Summary of Contents for Boostassio Tube Power Boost

Page 1: ...Tube Power Boost Owner s Manual ...

Page 2: ...to react to and reproduce large changes in volume or string attack If you hit your strings hard and the tone seems thin and squeezed rather than fat and snappy you may be experiencing com pression due to lack of dynamic range Boostassio is a high voltage pentode tube design which produces greater dynamic range than a typical pedal This coupled with a vari able bias control produces not only a rang...

Page 3: ...storted and unbalanced causing greater degrees of interesting distortion and overdrive effects Start with this control set fully counterclockwise Set the Volume at around 9 o clock and gradu ally turn up the Bias As the bias is increased also increase the volume slightly to compensate for the reduction in output level caused by the bias control You may hear a slight rushing noise as you turn the B...

Page 4: ...The external power supply connector is a 5 5x2 5mm barrel type Specifications Input Impedance 1M ohm Output Impedance 100K ohm Power Input Connector 2 5mm x 5 5mm Operating Voltage 12VAC Maximum Voltage 14VAC Current Consumption 500mA Tube Requirement EF86 6267 or equivalent NOT INTER CHANGEABLE WITH A 12AX7 OR ANY OTHER TYPE Dimensions 5 W x 4 75 D x 1 25 H Weight 1 5 Pounds ...

Page 5: ...tar And once you add sufficient boost to over load the front of your amplifier there will be some interesting frequency shifting depending on the amp and how it reacts to being boosted Every amp will react differently to what extent depends on your gear and the various settings playing volume other effects etc Neck or Bridge pick up Guitar volume down 1 or 2 notches Guitar tone full up Neck pick u...

Page 6: ...ctive EC1907 206 for the Registration Evaluation Authorization and Restriction of chemicals REACh and contain none or less than 0 1 of the chemicals listed as hazardous chemi cals in the REACh regulation All information provided in this Certificate of Compliance is accurate to the best of our knowledge as of the date this Certification was issued Declaration of Conformity EMC and Low Voltage Direc...

Page 7: ...ts necessitated by any cause beyond the control of SFD including but not limited to any malfunction defects or failure caused by or resulting from unauthorized service or parts damaged or broken tubes incorrect line voltage improper maintenance modification or repair by the user abuse misuse neglect accident fire flood or other Acts of God 5 Responsibility for the repair of any SFD product sold ou...

Page 8: ......

Reviews: