PIPING TO AND FROM THE PUMP
Using a thick walled pipe reduces the ambient noise effect. Clean the inside of the pipes prior to installation
to prevent foreign debris from getting inside the pump and causing damage. Don’t create short radius curves.
Pipes should be seperately supported, not by the pump. The pump should be isolated from the pipes by
means of flexible connections fitted between the silencers, suction filter and the ports.
PRESSURE RELEIF VALVE
Usually the valve is supplied unadjusted.
ASSEMBLING LAyOUT
1 Secondary shut-off valve
2 4 way valve
3 Suction filter
4 Pump
5 Check valve
6 Check valve
7 Silencer
8 Silencer
9 Vacuum control valve
10 Pressure reliefe valve
11 Temperature thermocouple
VACUUM MODE