MAN
U
FACTURER DECLARATION
MOD.
...............................................................................................................................................
SERIAL NUMBER
........................................................................................................
YEAR
...............................................................................................................................................
The pump should not be operated until verification can be provided that the installation conforms to
directive
2006/42/CE
and any current revisions. Always be sure that the installation of
the
pump conforms to all
applicable installation and operational requirements pertaining to the country and region for which its use is
intended.
PUMP FEATURES
VACUUM PERFORMANCES
MOD.
Q*
RPM
20%-6”Hg
50%-15”Hg
80%-24”Hg
90%-27”Hg
m3/h-cfm
m3/h-cfm
Kw
m3/h-cfm
Kw
m3/h-cfm
Kw
m3/h-cfm
Kw
FK1600
1600-950
2000
790-465
7
688-405
14
323-190
21
2500
986-580
9
860-505
18
400-235
26
BO*
3000
1215-715
11
1096-645
23
655-385
31
43-25
35
3500
1428-840
12
1292-760
25
888-522
37
187-110
41
FK2000
2300-1350
2000
1215-715
10
1020-600
20
357-210
32
2500
1547-910
12
1351-795
25
646-380
39
3000
1887-1110
14
1683-990
29
952-560
46
BO*
3300
2084-1226
16
1904-1120
34
1194-702
53
145-85
59
Q = Generated capacity / BO = Blanked Off
Summary of Contents for FB
Page 1: ...I FB Blowers ...
Page 4: ...B N B A C T 4HOLES s C j G S 0 w L M u ...
Page 19: ...SPARE PARTS ...