background image

In the interest of continual product development we reserve the right to change any of the 
details and specifications without notice. 

 

Page 17 

 

R290 refrigerant is used for this equipment. 

 

Caution! 

Consult repair manual/owner’s guide before attempting to install or service this product. All 
safety precautions must be followed. Dispose of properly in accordance with federal or local 
regulations. Risk of fire or explosion due to puncture of refrigerant tubing. Follow handling 
instructions carefully. 
 

Danger! 

Risk of fire or explosion. Flammable refrigerant used. To be repaired only by trained service 
personnel. Do not use mechanical devices to defrost refrigerator. Do not puncture refrigerant 
tubing. 
 

Disposal 

EU regulations require refrigeration product to be disposed of by specialist 
companies who remove or recyle all gasses,metal and plastic components.

 

Consult your local waste collection authority regarding disposal of your appliance. 

Enviromental protection 

Discarded electric appliances are recyclable and should not be discareded in the 
domestic waste! 

Compliance 

Parts have undergone strict product testing in order to comply with regulatory standards and 
specification set by international,independent,and federal authorities. 
Products have been approved to carry the following symbol. 
 
 

     

 

 

 

 

Summary of Contents for P75-150

Page 1: ...uration of the equipment and or the use of elements added without the authorisation of Frost Tech Limited may cause incorrect operation In the afore mentioned product groups only prepacked products wi...

Page 2: ...d is cooled 7 C or cooler ideally within 90 minutes Re heating Whenever food is re heated Minimum core temp of 70 C for 2 mins Hot food on display Frequently while on display Minimum core temp of 63 C...

Page 3: ...in regulation matter and as instructed in this manual Contact your service organisation if you are in any doubt about electrical connection working or safety of your plug in refrigerated cabinet When...

Page 4: ...make sure that the refrigeration unit fan is free to take in ambient air from the room via the front grill area and blow it off at the back Adhere to the specific minimum distance of 80mm When the ca...

Page 5: ...ge and there is no risk of tripping STARTING and COMMISSIONING If the cabinet has been sharply tilted while being sited or for counting of accessories it must be left to stand for at least three hours...

Page 6: ...in laboratory tests Regulation which is different from those recommended may be necessary for reasons of non standard ambient and or operating conditions The units are delivered with the regulation a...

Page 7: ...ter formed during the defrosting is performed automatically During automatic defrosting the temperature in the display compartment may rise slightly Defrost frequency as well as duration and time are...

Page 8: ...h a commercial brand alcohol based glass cleaner Cleaning the internal surfaces Remove the merchandise from the display compartment and transfer it to another storage place Do not start cleaning befor...

Page 9: ...steps to prevent the deterioration of the product i e destocking and removal of the product to an operational storage facility Where operational faults are detected check the electrical protection and...

Page 10: ...to preventative maintenance every three months a the parties concerned for the refrigerating system must ensure that the system is inspected regularly supervised and maintained in a satisfactory mann...

Page 11: ...shall only be put into service again when all the leaks have been repaired During each periodic maintenance and following each repair the following tasks shall be performed a all safety control and m...

Page 12: ...g must be designed taking into consideration electrical characteristics of the compressor condensing unit and its electrical components WARNING For applications designed to be used with flammable refr...

Page 13: ...the low and high side achieving a minimum level of 0 14 mbar 100 Hg with a non condensable value of less than 0 3 WARNING Avoid the compressor condensing unit starting under vaccum or without refriger...

Page 14: ...ING For compressor condensing unit replacement follow the instructions of the original equipment manufacturer Use only with electrical components specified by the manufacturer WARNING On applications...

Page 15: ...he merchandise from the display compartment and transfer to another storing place Unplug power plug or switch off control switch If the cabinet is to be shut down for any length of time clean cabinet...

Page 16: ...inor temperature rise during defrosting is normal b ambient temperature too high or Avoid extreme operating environment i e temperature over 25 Adjust storage temperature controller c distance to wall...

Page 17: ...erant used To be repaired only by trained service personnel Do not use mechanical devices to defrost refrigerator Do not puncture refrigerant tubing Disposal EU regulations require refrigeration produ...

Reviews: