G-H
Gas post-flow time at maximum
welding current
G-L
Gas post-flow time at minimum
welding current
2-step mode
-
Welding: Pull back and hold the torch trigger
-
End of welding: Release the torch trigger
I
t
I
1
G-L / G-H
GPr
t
S
P
U
down
2-step mode
4-step mode
-
Welding start-up with starting current I
S
: Pull back and hold the torch trig-
ger
-
Welding with main current I
1
: Release the torch trigger
-
Lowering to final current I
E
: Pull back and hold the torch trigger
-
End of welding: Release the torch trigger
I
t
I
1
GPr
I
S
t
S
P
U
down
I
E
I-2
G-L
G-H
I
1
*)
4-step mode
*) Intermediate lowering
Intermediate lowering during the main current phase reduces the welding cur-
rent to the specified reduced current I-2 reduced.
-
To activate intermediate lowering, push forward and hold the torch trigger
-
To revert to the main current, release the torch trigger
58
Summary of Contents for TransTig 1700
Page 2: ......
Page 19: ...General information 19...
Page 20: ...20...
Page 25: ...Control elements and connections 25...
Page 26: ...26...
Page 45: ...Installation and commissioning 45...
Page 46: ...46...
Page 55: ...Welding 55...
Page 56: ...56...
Page 72: ...72...
Page 73: ...Setup settings 73...
Page 74: ...74...
Page 87: ...Troubleshooting and maintenance 87...
Page 88: ...88...
Page 96: ...96...
Page 97: ...Appendix 97...
Page 98: ...98...
Page 124: ......