Connecting up the mains cable on US power
sources
General
The US power sources are supplied without a mains cable. A mains cable appro-
priate for the connection voltage must be fitted prior to commissioning.
A strain-relief device for a cable cross-section AWG 10 is installed on the power
source. Strain-relief devices for larger cable cross-sections must be designed ac-
cordingly.
Stipulated mains
cables and
strain-relief
devices
Power source
Mains voltage
Cable cross-sec-
tion
TT 4000/5000 MV Job, MW
4000/5000 MV Job
3 x 380 - 460 V
3 x 200 - 240 V
AWG 10
AWG 6
AWG ...
A
merican
W
ire
G
auge
Safety
WARNING!
Danger due to work that has been carried out incorrectly.
This can result in serious injury and damage to property.
▶
The work described below must only be carried out by trained and qualified
personnel.
▶
Observe national standards and directives.
CAUTION!
Danger due to improperly prepared mains cable.
This can cause short circuits and damage.
▶
Fit ferrules to all phase conductors and the ground conductor of the
stripped mains cable.
Connecting the
mains cable
1
Remove the left side panel of the power source
2
Strip about 100 mm (4 in.) of insulation from the end of the mains cable
NOTE!
The ground conductor (green, or green with yellow stripes) should be ap-
prox. 10 - 15 mm (0.4 - 0.6 in.) longer than the phase conductors.
50
Summary of Contents for TransTig 1700
Page 2: ......
Page 19: ...General information 19...
Page 20: ...20...
Page 25: ...Control elements and connections 25...
Page 26: ...26...
Page 45: ...Installation and commissioning 45...
Page 46: ...46...
Page 55: ...Welding 55...
Page 56: ...56...
Page 72: ...72...
Page 73: ...Setup settings 73...
Page 74: ...74...
Page 87: ...Troubleshooting and maintenance 87...
Page 88: ...88...
Page 96: ...96...
Page 97: ...Appendix 97...
Page 98: ...98...
Page 124: ......