CAUTION!
An inadequately dimensioned electrical installation can cause serious damage.
▶
The mains lead and its fuse must be dimensioned to suit the local power sup-
ply. The technical data shown on the rating plate applies.
Generator-
powered opera-
tion (MW 1700 /
2200, TT 2200)
The MW 1700/2200 and TT 2200 power sources are generator-compatible,
provided that the maximum apparent power delivered by the generator is at least
10 kVA.
IMPORTANT!
The voltage delivered by the generator must never exceed the up-
per or lower limits of the mains voltage tolerance range. Details of the mains
voltage tolerance can be found in the "Technical data" section.