![Fronius TransTig 1700 Operating Instructions Manual Download Page 48](http://html1.mh-extra.com/html/fronius/transtig-1700/transtig-1700_operating-instructions-manual_2339442048.webp)
Before installation and commissioning
Safety
WARNING!
Danger due to incorrect operation and incorrectly performed work.
This can result in severe personal injury and damage to property.
▶
All the work and functions described in this document must only be carried
out and used by trained and qualified personnel.
▶
Fully read and understand this document.
▶
Fully read and understand all the Operating Instructions for the system
components, especially the safety rules.
Utilisation for in-
tended purpose
The power source is intended exclusively for TIG and MMA welding.
Utilisation for any other purpose, or in any other manner, shall be deemed to be
not in accordance with the intended purpose.
The manufacturer shall not be liable for any damage resulting from such improp-
er use.
Proper use also includes:
-
following all the information in the operating instructions
-
carrying out all the specified inspection and servicing work
Setup regula-
tions
The device is tested to IP 23 protection, meaning:
-
Protection against penetration by solid foreign bodies with diameters > 12.5
mm (0.49 in.)
-
Protection against spraywater at any angle up to 60° to the vertical
The device can be set up and operated outdoors in accordance with degree of
protection IP 23.
Avoid direct wetting (e.g. from rain).
WARNING!
Toppling or falling devices can cause life-threatening injuries.
▶
Place devices on a solid, level surface so that they remain stable.
The venting duct is a very important safety device. When choosing the installa-
tion location, ensure that the cooling air can enter and exit unhindered through
the air ducts on the front and back of the device. Electroconductive metallic
dust (e.g. from grinding work) must not be allowed to get sucked into the device.
Mains connec-
tion
The devices are designed for the mains voltage specified on the rating plate. If
your version of the appliance does not come with mains cables and plugs ready-
fitted, these must be fitted in accordance with national regulations and stand-
ards. For details of fuse protection of the mains lead, please see the technical
data.
48
Summary of Contents for TransTig 1700
Page 2: ......
Page 19: ...General information 19...
Page 20: ...20...
Page 25: ...Control elements and connections 25...
Page 26: ...26...
Page 45: ...Installation and commissioning 45...
Page 46: ...46...
Page 55: ...Welding 55...
Page 56: ...56...
Page 72: ...72...
Page 73: ...Setup settings 73...
Page 74: ...74...
Page 87: ...Troubleshooting and maintenance 87...
Page 88: ...88...
Page 96: ...96...
Page 97: ...Appendix 97...
Page 98: ...98...
Page 124: ......