Grid voltage
Country-specific setting
Power source fuse rating
Welding current limitation
120 V
US
15 A
MIG/MAG welding:
max. 105 A; 80 A at 100%*
SMAW:
max. 90 A; 70 A at 100%*
TIG welding:
max. 135 A; 105 A at 100%*
120 V
Std
16 A
MIG/MAG welding:
max. 115 A; 105 A at 100%*
SMAW:
max. 100 A; 85 A at 100%*
TIG welding:
max. 140 A; 130 A at 100%*
120 V
US
20 A
MIG/MAG welding:
max. 135 A; 105 A at 100%*
SMAW:
max. 110 A; 90 A at 100%*
TIG welding:
max. 160 A; 130 A at 100%*
230 V
Std
10 A
MIG/MAG welding:
max. 145 A; 110 A at 100%*
SMAW:
max. 125 A; 90 A at 100%*
TIG welding:
max. 180 A; 135 A at 100%*
230 V
Std
13 A
MIG/MAG welding:
max. 170 A; 140 A at 100%*
SMAW:
max. 150 A; 120 A at 100%*
TIG welding:
max. 200 A; 160 A at 100%*
230 V
Std
16 A
MIG/MAG welding:
max. 210 A; 150 A at 100%*
SMAW:
max. 180 A; 130 A at 100%*
TIG welding:
max. 230 A; 170 A at 100%*
240 V
US
15 A
MIG/MAG welding:
max. 210 A; 150 A at 100%*
SMAW:
max. 180 A; 130 A at 100%*
TIG welding:
max. 230 A; 170 A at 100%*
A 20 A fuse can only be selected if:
-
The country-specific setting has been set to "US"
-
The grid lead has a 20 A fuse
-
The power source is supplied with a grid voltage of 120 V
* 100% values = welding with no time limits and without cooling breaks.
The welding current data applies at an ambient temperature of 40 °C (104 °F).
A safety cut-out prevents the automatic circuit breaker from tripping at higher welding
powers. The safety cut-out defines the possible welding duration without the automatic
47
EN-US
Summary of Contents for TransSteel 2200
Page 2: ......
Page 18: ...18...
Page 19: ...General information 19...
Page 20: ...20...
Page 22: ...Application areas MIG MAG welding TIG welding Manual metal arc welding 22...
Page 29: ...Operating controls and connections 29...
Page 30: ...30...
Page 40: ...40...
Page 41: ...Before installation and initial opera tion 41...
Page 42: ...42...
Page 50: ...Fitting the Carrying Strap Fitting the carry ing strap to the power source 1 2 3 4 5 6 50...
Page 51: ...MIG MAG 51...
Page 52: ...52...
Page 55: ...Inserting the D100 wirespool 1 2 Inserting the D200 wirespool 1 2 3 55 EN US...
Page 73: ...TIG 73...
Page 74: ...74...
Page 75: ...Commissioning Start Up 1 2 3 4 5 75 EN US...
Page 83: ...Rod Electrode 83...
Page 84: ...84...
Page 88: ...For a parameter description see section Parameters for MMA Welding from page 99 88...
Page 89: ...EasyJobs 89...
Page 90: ...90...
Page 92: ...92...
Page 93: ...Setup Menu 93...
Page 94: ...94...
Page 104: ...104...
Page 105: ...Optimizing Weld Quality 105...
Page 106: ...106...
Page 110: ...110...
Page 111: ...Troubleshooting and Maintenance 111...
Page 112: ...112...
Page 124: ...124...
Page 125: ...Appendix 125...
Page 126: ...126...
Page 134: ...134...
Page 135: ...135 EN US...