56
Before commissioning
Safety
WARNING!
Danger from incorrect operation.
Possible serious injury and damage to property.
► Do not use the functions described here until you have read and completely under
-
stood these Operating Instructions.
► Do not use the functions described here until you have fully read and understood all of
the Operating Instructions for the system components, in particular the safety rules!
Setup regulations
WARNING!
If one of these devices topples over or falls it could cause serious or even fatal inju
-
ry.
Place units on a solid, level surface so that they remain stable.
The device is tested to IP 23 protection, meaning:
-
protection against penetration by solid foreign bodies with diameters > 12 mm (0.49
in.)
-
protection against direct sprays of water at any angle up to 60° from the vertical
Cooling air
The system must be set up in such a way that cooling air can flow unimpeded through the
slots in the front and rear panels.
Dust
Ensure that any metallic dust, for example from grinding work, is not sucked into the sys
-
tem by the fan.
Outdoor operation
The device can be set up and operated outdoors in accordance with IP23 degree of pro
-
tection. Direct wetting (e.g. from rain) should be avoided.
Mains connection
The device is designed to run at the mains voltage indicated on the rating plate. The re
-
quired fuse protection for the mains supply can be found in the "Technical data" section. If
there is no mains cable or mains plug on your device, fit one that conforms to national
standards.
NOTE!
Inadequately dimensioned electrical installations can cause serious damage.
The incoming mains lead and its fuse must be dimensioned to suit the local power supply.
The technical data shown on the rating plate applies.
Generator-pow
-
ered operation
The power source is generator-compatible, provided that the maximum apparent power
delivered by the generator is at least 22 kVA.