= 15 mm
= 5 mm
= 5 mm
= 5
(0.59 inch)
mm
-
The wire electrode will not be unwound any fur-
ther once the set Stickout- value has been
reached, even if the wire electrode is no longer in
contact with the workpiece.
The Touch signal is set as follows when using Teach mode:
-
As soon as the wire electrode touches the workpiece, the Touch signal is set to High
-
Only when the wire electrode is no longer in contact with the workpiece is the Touch
signal set to Low
NOTE!
Danger from using Teach mode in conjunction with very soft wire electrodes.
This may result in unexpected welding results caused by bent wire electrodes.
▶
Using Teach mode with very soft wire electrodes may result in the wire electrodes
becoming bent. To prevent wire burn-back caused by the bent wire electrode,
unwind the wire electrode by approx. 50 cm (19.69 inches) before the start of weld-
ing and shorten it.
Additional information for TWIN systems:
-
In single wire mode, Teach mode is activated for the active process line
-
In TWIN mode, Teach mode is activated for both process lines
ExtInput 1-8
(External input
1-8) - Single Bit
Inputs used to control options, such as OPT/i RI FB REL.
-
Max. voltage = DC 113 V / AC 68 V
-
Max. current load 1 A
Example outputs: ExtInput1 = OPT_Output 1:
OPT/i RI
FB REL
(1)
External
Device
(2)
(3)
(1)
Robot output
(2)
Power source input
(3)
Options output