Connecting the data communication cable
Routing data
communication
cables
IMPORTANT!
If data communication cables are wired into the inverter, observe the following points:
-
Depending on the number and cross section of the wired data communication
cables, remove the corresponding blanking plugs from the sealing insert and insert
the data communication cables.
-
Make sure that you insert the corresponding blanking plugs into any free openings
on the sealing insert.
IMPORTANT!
Should the blanking plugs be missing or improperly fitted, then protection class IP66 can-
not be guaranteed.
1
Undo the strain-relief device cap nut and
push out the sealing ring and the blanking
plug from the inside of the device.
2
Open up the sealing ring at the location
where the blanking plug is to be removed.
*
Liberate the blanking plug by moving it
sideways.
73
EN