Keys and symbols
Keys and Sym-
bols
The keys have a capacitive function. Wetting the keys with water may impair their function.
For optimal function, wipe the keys with a dry cloth if necessary.
Item
Description
(1)
Display
for displaying values, settings and menus
Control and Status LEDs
(2)
Initializing LED (red) is illuminated,
-
during the initialization phase when starting-up the inverter
-
permanently if a hardware defect occurs when starting up the inverter in the
initialization phase
(3)
Status LED (orange) is illuminated, if
-
the inverter is in the automatic startup or self test phase after the initializa-
tion phase (as soon as the solar modules yield sufficient power output after
sunrise)
-
State codes are shown on the inverter display
-
if the inverter has been set to standby operation in the setup menu (= man-
ual shutoff of grid power feed operation)
-
if the inverter software is being updated
(4)
Operating LED (green) is illuminated,
-
if the photovoltaic system is operating without errors after the inverter’s au-
tomatic start-up phase
-
as long as energy is being fed into the grid
Function keys - each has a different function depending on the selection:
(5)
‘Left/Up’ key
for navigating left and up
(6)
‘Down/Right’ key
for navigating down and right
(7)
'Menu/Esc' key
for switching to the menu level
to exit the Setup menu
(8)
'Enter' key
for confirming a selection
(1)
(2)
(3)
(4)
(5)
(6)
(7) (8)