Charging lights
(4)
(5)
(+)
( - )
(1)
(2)
(3)
RCS 3.0
Lights
1
2
3
4
12V
GREEN
YELLOW
RED
BLUE
Ext. Start/Stop
Ext. Start/Stop
WARNING
Hazardous Voltage
Kondensator Entladezeit < 2 min.
Capacitor discharge time < 2 min.
Décharge de condensateur < 2 min.
Condensador tiempo de descarga < 2 min.
Condensatore tempo di scaricamento < 2 min.
Suitable signal lamps can be connected to the connections inside the device as
illustrated in order to indicate the state of charge or operating status of the char-
ger. Each signal lamp must have a working voltage of 12 V, and the total current
drawn by all the lamps must not exceed 0.5 A. Connections (1) to (5) in the figure
are assigned as shown below. It is advisable to use the lamp colours shown below:
Connection Function
Colour
(1)
12 V power supply
(2)
"Battery charged" indicator
-
On steady: charging ended
Green
(3)
"Charge" indicator
-
Lit: during charging
-
Flashes: if charging has been interrupted
Yellow
(4)
"Fault" indicator on steady:
-
Charger faulty
-
While the red indicator is on, charging cannot
take place (charging interrupted).
-
The relevant status code appears in the display.
"Fault" indicator flashes briefly every 3 seconds:
-
The charger outputs a status code.
-
Charging continues. The relevant status code
number and the state of charge appear altern-
ately on the display.
Red
(5)
"State of charge" / "Battery cooled down" on steady:
-
Depending on the indicator function that has
been set, either the state of charge has exceeded
the set percentage value or the battery has
cooled down and is ready for use.
Blue
If the RGB setting (LED strip) is set in the menu, then connection 3 (YELLOW) is
not supported. The normal setting (conventional signal lamp) or RGB (LED strip)
for the "External lamp" function is explained under "Additional functions" in the
"Display" section.
Wall bracket
The robust wall bracket ensures safe fitting on site. More information can be
found in the corresponding Installation Instructions.