Program
ON 1
OFF 1
Repeat
ON 2
OFF 2
1
30 min
25 min
1 x
5 min
25 min
2
3 min
10 min
4 x
3 min
20 min
3
3 min
12 min
1 x
3 min
12 min
4
5 min
10 min
3 x
5 min
20 min
5
2,5 min
7,5 min
1 x
2,5 min
7,5 min
In each of these programs, the solenoid valve picks up for an "ON 1" time and
drops out for an "OFF 1" time. This process repeats as many times as specified
for "Repeat". After this number of repetitions has elapsed, the "ON 2" and "OFF
2" times continue until the end of charging.
Temperature-
controlled char-
ging
Temperature-controlled charging:
The following settings are available for temperature-controlled charging:
automatic/OFF/required
-
automatic ... Temperature-dependent adjustment of the charging character-
istic.
-
OFF ... The measured battery temperature is not taken into account.
-
required ...
Charging only starts when the temperature sensor is connected.
Error overtemperature ON/OFF
-
ON ... An error message is output in the event of a battery overtemperature.
The charging process stops and can only be continued after the battery has
cooled down and been reconnected.
-
OFF ... No error message in the event of a battery overtemperature.
Warning overtemperature ON/OFF
-
ON ... A warning is output in the event of a battery overtemperature.
-
OFF ... No warning in the event of a battery overtemperature.
For certain curves, an external temperature sensor is required. If such a curve is
selected in configuration mode, a message is displayed indicating that an external
temperature sensor is required.
The following curves require an external temperature sensor:
-
28 - FCC IUI - CSM WET
-
30 - FCC IUI - WET
41
EN-US