Weekly
-
Empty collecting tray;
clean screen for collecting tray if available
-
Blow out the intake filter in the parting agent container from the inside out with com-
pressed air using the intake hose
-
Drain water in the pressure booster (press red button on the glass tank)
Monthly
-
Open the dirt deflector under the round brushes and clean with compressed air
Every 6 Months
CAUTION!
Risk of damage to electronic parts.
▶
Do not blow electronic parts clean from a short distance away.
1
Open the welding torch service station and blow clean with dry and reduced com-
pressed air
Every 12 Months
1
Have a Fronius service technician perform a safety inspection on the cleaning device
Disposal
Materials should be disposed of according to valid local and national regulations.