Outer gas
nozzles cleaning
brush program
sequence
Move to position E
approx. 50 mm/1.97 in. centrally above
the outer gas nozzle cleaning brush and
approx. 20 mm/0.79 in. in front of the
housing of the service station
Position welding torch at an angle
Speed: High-speed mode
E
50 mm
1.97 in.
20 mm
0.79 in.
Set
external signal "External valve brush
cleaning"
Move into the external gas nozzle
cleaning brush
max. speed: 50 cm/min / 19.69 ipm
max. insertion depth: 12 mm / 0.47 in.
Pass through the external gas nozzle
cleaning brush x2
forwards and backwards
max. speed: 50 cm/min / 19.69 ipm
max. insertion depth: 12 mm / 0.47 in.
Turn welding torch 180°
*)
*) Alternative:
Break the second cleaning brush free
and pass through each cleaning brush x
1
Pass through the external gas nozzle
cleaning brush x2
forwards and backwards
max. speed: 50 cm/min / 19.69 ipm
max. insertion depth: 12 mm / 0.47 in.
Wait approx. 2-3
seconds
Reset
external signal "External valve brush
cleaning"
76
Summary of Contents for Robacta TSS /i
Page 2: ......
Page 11: ...General 11 ...
Page 12: ...12 ...
Page 18: ...18 ...
Page 19: ...Operating controls connections and mechanical components 19 ...
Page 20: ...20 ...
Page 32: ...32 ...
Page 33: ...Installation and Startup 33 ...
Page 34: ...34 ...
Page 61: ...12 12 12 Connect the compressed air supply 61 EN US ...
Page 64: ...64 ...
Page 65: ...Cleaning Program Sequence 65 ...
Page 66: ...66 ...
Page 68: ...A B C D E F G 68 ...
Page 79: ...Reset external signal Internal valve brush cleaning 79 EN US ...
Page 84: ...Reset external signal Cut wire electrode End of the cleaning process Welding 84 ...
Page 85: ...Troubleshooting Maintenance and Disposal 85 ...
Page 86: ...86 ...
Page 97: ...Appendix 97 ...
Page 98: ...98 ...