
TC 2000 program
sequence
Move to position C
approx. 50 mm/1.97 in. centrally above
cleaning coil
Speed: High-speed mode
C
50 mm
1.97 in.
*)
Insertion depths for coil shapes
other than Twin as per Robacta
TC 2000 Operating Instructions
Move into TC 2000
max. speed: 50 cm/min / 19.69 ipm
Insertion depth: 54 mm / 2.13 in. *)
Set
external signal "Start cleaning"
Wait 0.5 seconds
Reset
external signal "Start cleaning"
Move to position C
approx. 50 mm/1.97 in. centrally above
cleaning coil
max. speed: 50 cm/min (19.69 ipm)
73
EN-US
Summary of Contents for Robacta TSS /i
Page 2: ......
Page 11: ...General 11 ...
Page 12: ...12 ...
Page 18: ...18 ...
Page 19: ...Operating controls connections and mechanical components 19 ...
Page 20: ...20 ...
Page 32: ...32 ...
Page 33: ...Installation and Startup 33 ...
Page 34: ...34 ...
Page 61: ...12 12 12 Connect the compressed air supply 61 EN US ...
Page 64: ...64 ...
Page 65: ...Cleaning Program Sequence 65 ...
Page 66: ...66 ...
Page 68: ...A B C D E F G 68 ...
Page 79: ...Reset external signal Internal valve brush cleaning 79 EN US ...
Page 84: ...Reset external signal Cut wire electrode End of the cleaning process Welding 84 ...
Page 85: ...Troubleshooting Maintenance and Disposal 85 ...
Page 86: ...86 ...
Page 97: ...Appendix 97 ...
Page 98: ...98 ...