Adjusting the
parting agent
nebuliser spray
amount
NOTE!
To ensure that the spray amount is adjusted properly, the welding torch must be
in the cleaning position.
1
Establish a compressed air supply to the cleaning device
2
Connect the cleaning device to the robot control
3
Start the spraying process using the robot control and check that sufficient
spray is being applied
4
If the spray amount is not sufficient, increase it as required
-
by adjusting the spray time using the robot control - a spray time of ~ 0.7
seconds is recommended (nur Robacta Reamer V only)
-
or by using the parting agent adjuster - see figure below
1
-
+
Finely adjusting the spray amount on parting agent adjuster
46