(2)
(2) LED NS - Network status
Off:
No supply voltage or no IP address
Lights up green:
Online, one or more connections es-
tablished (CIP category 1 or 3)
Flashes green:
Online, no connection established
Lights up red:
Double IP address, serious error
Flashes red:
Overrun of time for one or more
connections (CIP category 1 or 3)
Data Transfer
Properties
Transfer technology
Ethernet
Medium
When selecting the cables and plugs, the ODVA recommendation for the plan-
ning and installation of EtherNet/IP systems must be observed.
The EMC tests were carried out by the manufacturer with the cable IE-
C5ES8VG0030M40M40-F.
Transmission speed
10 Mbit/s or 100 Mbit/s
Bus connection
RJ-45 Ethernet / M12
Configuration
Parameters
In some robot control systems, it may be necessary to state the configuration pa-
rameters described here so that the bus module can communicate with the ro-
bot.
Parameter
Value
Description
Vendor ID
0534
hex
(1332
dec
)
Fronius International GmbH
Device Type
000C
hex
(12
dec
)
Communication adapter
Product Code
0320
hex
(800
dec
)
Fronius FB Pro Ethernet/IP-2-Port
Product Name
Fronius-FB-Pro-EtherNetIP(TM)
Image Type
Instance
Type
Instance
Name
Instance
Description
Instance
Number
Size
[Byt
e]
Standard
Image
Produ-
cing In-
stance
Input Da-
ta Stan-
dard
Data from power
source to robot
100
40
23