Connecting backup power - Full Backup
Safety
The examples given in this document (in particular cabling variants and Circuit Dia-
grams) are suggestions only. These examples have been carefully developed and
tested. They can therefore be used as a basis for real-life installation. Anyone following
or using these examples does so at their own risk.
IMPORTANT!
The valid national laws, standards and provisions, as well as the specifications of the rel-
evant grid operator are to be taken into account and applied.
It is highly recommended to coordinate the concrete examples implemented and in par-
ticular the specific installation with the grid operator to obtain their explicit approval. This
obligation applies to system constructors in particular (e.g. installers).
The examples suggested here show a backup power supply with or without an external
protection relay (external grid and system protection unit). Whether an external protec-
tion relay must be used or not is the decision of the respective grid operator.
IMPORTANT!
No uninterruptible power supply (UPS) must be operated in the backup power circuit.
The Installation and Operating Instructions must be read carefully prior to use. If anything
is unclear, contact your vendor immediately.
WARNING!
Danger from incorrect installation, commissioning, operation or incorrect use.
This can result in severe personal injury/damage to property.
▶
Only trained and qualified personnel are authorised to install and commission the
system, and only within the scope of the technical regulations.
▶
The Installation and Operating Instructions must be read carefully prior to use.
▶
If anything is unclear, contact your vendor immediately.
Cabling variants
including backup
power circuits
with 1-pin separa-
tion e.g. Austria
or Australia
Circuit Diagram
The Circuit Diagram for the 1-pin double separation - e.g. Austria, can be found in the
appendix to this document on page
.
The Circuit Diagram for the 1-pin single separation - e.g. Australia, can be found in the
appendix to this document on page
.
Cabling of backup power circuit and non-backup power circuits
If not all the loads in the home need to be supplied in a backup power situation, the cir-
cuits need to be divided into backup power circuits and non-backup power circuits. The
total load of the backup power circuits must not exceed the nominal output of the
inverter.
The backup power circuits and non-backup power circuits must be fused separately
according to the required safety measures (residual current circuit breaker, automatic cir-
cuit breaker, etc.).
In backup power mode, only the backup power circuits are disconnected from the grid by
contactors K1 and K2, 1-pin. The rest of the home network is not supplied with power in
this case.
75
EN
Summary of Contents for Primo GEN24 3.0 Plus
Page 2: ......
Page 11: ...General information 11...
Page 12: ...12...
Page 31: ...Backup power variant PV Point OP 31...
Page 32: ...32...
Page 34: ...34...
Page 35: ...Backup power variant Full Backup 35...
Page 36: ...36...
Page 43: ...Installation 43...
Page 44: ...44...
Page 50: ...Do not install the inverter on the ceiling 50...
Page 84: ...84...
Page 90: ...90...
Page 91: ...Settings website of the inverter 91...
Page 92: ...92...
Page 110: ...I O power man agement settings 4 relays 110...
Page 112: ...I O power man agement settings 3 relays 112...
Page 114: ...I O power man agement settings 2 relays 114...
Page 118: ...118...
Page 119: ...Options 119...
Page 120: ...120...
Page 129: ...Appendix 129...
Page 130: ...130...
Page 143: ...Circuit diagrams 143...
Page 144: ...144...
Page 145: ...Circuit Diagram PV Point OP Circuit Diagram 145 EN...
Page 146: ...Fronius Primo GEN24 and BYD Battery Box Premium HV Circuit Diagram 146...
Page 147: ...Automatic switch to backup power 1 pin double separation e g Austria Circuit Diagram 147 EN...
Page 148: ...Automatic switch to backup power 1 pin single separation e g Australia Circuit Diagram 148...
Page 149: ...Automatic switch to backup power 2 pin double separation e g Germany Circuit Diagram 149 EN...
Page 150: ...Automatic switch to backup power 2 pin single separation e g France Spain Circuit Diagram 150...
Page 151: ...Automatic switch to backup power 2 pin double separation e g UK Circuit Diagram 151 EN...
Page 153: ...Fronius Primo GEN24 with Enwitec Box Circuit Diagram 153 EN...
Page 154: ...Wiring diagram surge protective device SPD Circuit Diagram 154...
Page 155: ...Dimensions of the inverter 155...
Page 156: ...156...
Page 157: ...Fronius Primo GEN24 3 6 kW Fronius Primo GEN24 3 6 kW 157 EN...
Page 158: ...158...
Page 159: ...159 EN...