![Fronius Primo 208-240 Service Manual & Spare Parts List Download Page 105](http://html1.mh-extra.com/html/fronius/primo-208-240/primo-208-240_service-manual-and-spare-parts-list_2339193105.webp)
105
EN-US
Class 7–10 Ser-
vice Codes
Class 7 status codes concern the inverter control unit, configuration and data recording,
and can directly or indirectly affect grid feed operation.
604
Temperature sensor at
DC2 faulty (Ch4)
1. Faulty temperature sensor
at DC2
1. Replace DC PC board
2. Faulty circuit on power mod-
ule
2. Replace AC PC board
607
Error message from the
RCMU more than 4 times in
24 hours
1. Ground problem
1. Automatically corrected after
24 hours
2. Check PV field
3. Check cabling
Code
Description
Behavior
Remedy
Code
Description
Behavior
Remedy
701*
LN node type outside of
range
1. Incorrect LN number
1. Enter LN number again
2. EEPROM faulty
2. Replace Recerbo
702*
Recerbo buffer full
1. Problems with LN ring
1. Check LN ring
2. Recerbo faulty
2. Replace Recerbo
703*
LN transmission buffer full
1. Problems with LN ring
1. Check LN ring
2. Recerbo faulty
2. Replace Recerbo
705*
LN number double assign-
ment
1. LN number exists 2 times
1. Change LN number; LN
number must be unique
706*–707*
Communication error for
key activation
1. Occurs once
1. Automatically corrected
2. Recerbo faulty
2. Replace Recerbo
711*
EEPROM fault
1. Recerbo faulty
1. Replace Recerbo
712*
Error when writing to EE-
PROM
1. Occurs once
1. Automatically corrected
713
EEPROM data could not be
read completely
1. Occurs once
1. Automatically corrected
2. Recerbo faulty
2. Replace Recerbo
714*–715*
Error when reading EE-
PROM
1. Occurs once
1. Automatically corrected
2. Recerbo faulty
2. Replace Recerbo
721
Error when writing to EE-
PROM
1. Occurs once
1. Automatically corrected
2. Recerbo faulty
2. Replace Recerbo
722*–726*
Error when reading/writing
to EEPROM
1. Occurs once
1. Automatically corrected
2. Recerbo faulty
2. Replace Recerbo
727*–730*
EEPROM backup faulty
1. Occurs once
1. Automatically corrected
2. Recerbo faulty
2. Replace Recerbo
731
Error when initializing: USB
flash drive not found
1. USB flash drive read/write-
protected
1. Remove read/write-protec-
tion
2. USB flash drive not found
2. Format USB flash drive
3. USB flash drive not support-
ed
3. Use a different USB flash
drive
4. Access time of inverter too
fast
4. Update software
732
Error when initializing: USB
flash drive current is too
high
1. USB flash drive not suitable
due to high current
1. Use a different USB flash
drive
Summary of Contents for Primo 208-240
Page 2: ...2...
Page 5: ...Allgemeine Informationen...
Page 6: ......
Page 14: ...14...
Page 15: ...Fehler Suchhilfe...
Page 16: ......
Page 34: ...34...
Page 35: ...Komponenten austauschen...
Page 36: ......
Page 55: ...55 DE DC Trenner auf ON stellen 6...
Page 66: ...66...
Page 67: ...Sicherheitstechnische berpr fung...
Page 68: ......
Page 80: ...80...
Page 83: ...General Information...
Page 84: ......
Page 92: ...92...
Page 93: ...Troubleshooting guide...
Page 94: ......
Page 112: ...112...
Page 113: ...Replacing components...
Page 114: ......
Page 133: ...133 EN US Set the DC disconnector to ON 6...
Page 144: ...144...
Page 145: ...Safety inspection...
Page 146: ......
Page 158: ...158...
Page 159: ...Appendix...
Page 162: ...162...
Page 163: ...163...