Fronius Personal Display DL Operating Instructions Manual Download Page 1

/ Battery Charging Systems / Welding Technology / 

Solar Electronics

42,0410,1818

003-17042012

Fronius Personal Display DL

Operating Instructions

System monitoring

EN-US

Summary of Contents for Personal Display DL

Page 1: ...Battery Charging Systems Welding Technology Solar Electronics 42 0410 1818 003 17042012 Fronius Personal Display DL Operating Instructions System monitoring EN US...

Page 2: ...0...

Page 3: ...ith the product Reading the instructions carefully will enable you to learn about the many different features it has to offer This will allow you to make full use of its advantages Please also note th...

Page 4: ...2...

Page 5: ...ly unit 17 Start up phase setting the date and time 17 Connecting to the Fronius Personal Display DL Box or inverter 19 Operating concept 21 General 21 Display modes 21 Activating display illumination...

Page 6: ...7 Safety 37 Checking the battery charge status 37 Charging batteries 38 Battery disposal 38 Troubleshooting 39 General 39 Troubleshooting 39 Resetting the Fronius Personal Display Card in the inverter...

Page 7: ...perate the equipment System require ments The Fronius Personal Display DL can be used with up to 15 of the following Fronius invert ers Fronius IG Fronius IG Plus Fronius IG Plus V Fronius CL Differen...

Page 8: ...1 x Fronius Sensor Card Box assigned no 1 1 x Fronius Public Display assigned no 1 Utilization in ac cordance with intended pur pose The Fronius Personal Display DL is designed only for use in photov...

Page 9: ...7 EN US Included system components Fronius Personal Display DL included components Fronius Personal Display Card included components Fronius Personal Display DL Box included componen ts USB 2 m...

Page 10: ...figures may also differ slightly from the operating elements of your de vice However the function of these operating elements is identical 1 2 3 4 5 6 7 8 Item Description 1 Display for displaying va...

Page 11: ...observation depending on which display mode is selected IMPORTANT The min and max values may not correspond to the absolute extreme values as the measured data are recorded at two second intervals app...

Page 12: ...h when the charge status approaches 0 IMPORTANT When the batteries discharge further the Fronius Personal Dis play DL switches to Sleep mode and discontinues wireless traffic No informa tion is shown...

Page 13: ...ents especially the safety rules WARNING An electric shock can be fatal Danger from grid voltage and DC volt age from solar modules The inverter connection area should only be opened by a licensed ele...

Page 14: ...s Fronius Personal Display DL Fronius Personal Display Card Fronius IG Fronius IG Plus Fronius CL inverters IMPORTANT The mounting bracket is part of the antenna Only fit the antenna to the mounting b...

Page 15: ...Only fit the antenna to the mounting bracket supplied with the antenna NOTE For systems with several inverters antennas must be at least 19 7 in 0 5 m apart so that communication with the Fronius Pers...

Page 16: ...y DL Box 1 Inverter 1 e g Fronius IG Plus 2 Inverter 2 e g Fronius IG Plus 3 Inverter n max 15 e g Fronius IG Plus 4 Fronius Com Card 5 Fronius Personal Display DL Box corresponds to the functionality...

Page 17: ...s Personal Display DL Using the included wall mounting device the personal display can be installed on the wall in any room or used as a tabletop device by turning the wall mounting device 90 Wall ins...

Page 18: ...Display DL Box or inverter Establishing pow er supply insert ing batteries The batteries delivered in the original packaging are already charged Make sure that batteries are inserted correctly After...

Page 19: ...iate power adapter to the power supply unit After the power supply unit is connected the display runs through the start up phase for setting the time and date Afterwards you can establish the connecti...

Page 20: ...layed the first digit of the hour flashes Time format HH MM 24 h Use the Up and Down keys to select a value for the first digit of the hour Press the Enter key The second digit of the hour flashes Rep...

Page 21: ...Fronius Personal Display DL Boxes can be entered since there is only one in the system For a configuration with Fronius Personal Display Cards the first inverter found is dis played e g IG 01 Press t...

Page 22: ...20 When the device cannot find any more in verters WAIT remains on the display Press the Esc key to stop the process The Fronius Personal Display DL is now ready to show all system power data 4...

Page 23: ...ilable for power data for a total system or for each in dividual inverter in the system Activatingdisplay illumination Press any key The display illumination is activated If no key is pressed for 10 s...

Page 24: ...erter During normal operation in the ALL menu the operating status LED remains dark When a service message is triggered for an inverter in the system the operating status LED begins to flash For more...

Page 25: ...play mode is shown e g Day display mode Displaying power data for the total system ALL or individual invert ers IGxx ALL Total system IGxx Individual inverter e g IG 01 Press the Enter key 1 2 3 Press...

Page 26: ...r The navigation arrows switch to up and down Use the Up and Down keys to display additional power data for the selected inverter Press the Enter key to access power data for additional inverters The...

Page 27: ...urrent supplied to the grid at the particu lar moment Amperes Grid frequency Hertz Solar module voltage Voltage of the solar modules at the mo ment of data display Volts Solar module current Current s...

Page 28: ...mmunication component is changed this changes the time on all devices con nected via Solar Net Output energy Energy fed into the grid over the period of time in question kWh MWh Due to the variety of...

Page 29: ...r ing observation period Watts Maximum grid voltage Highest reading of grid voltage V during observation period Minimum grid voltage Lowest reading of grid voltage V during observation period Maximum...

Page 30: ...lied by the electric utility company are relevant Yield Amount of money earned during the peri od of time in question currency can be se lected in the Setup menu As was the case for the output energy...

Page 31: ...give you access to inverter settings Accessing the Setup menu Press the Menu key MENU ALL is displayed Use the Left or Right keys to select Setup Press the Enter key The Setup menu s first menu item i...

Page 32: ...lashes Repeat steps 4 and 5 until the entire value flashes Press the Enter key Repeat steps 4 6 for units or other values to be set until the unit or value flashes Press the Enter key to save and ap p...

Page 33: ...ied SLEEP LCD Time value setting for the sleep mode The display turns off after the time has ex pired to save battery power Correction value setting for the Total ener gy display The correction value...

Page 34: ...s using the Up and Down keys Unit Setting range 0 7 Factory setting 7 Unit Setting range AUTO ON OFF Factory setting AUTO AUTO The display illumination will stop 10 seconds after the last time a key h...

Page 35: ...ess or press the Enter key to delete the inverter from the system VERSION Accesses and updates information about the Fronius Personal Display DL and asso ciated plug in card in the inverter Unit Displ...

Page 36: ...displayed Press the Enter key The display DEL LOG flashes Press the Esc key cancels the process or press the Enter key resets saved data WAIT is displayed the data are deleted The Fronius Personal Dis...

Page 37: ...configured with the Fronius Personal Display DL Card the Fronius Personal Display DL does not log data if another data logger is present in the system e g Fronius Datalogger or Fronius Datalogger Web...

Page 38: ...tions on the PC laptop Insert the CD ROM Select the Fronius Solar access folder Run the setup exe file Follow the instructions of the installation wizard Install the USB driver Solar access Driver USB...

Page 39: ...ATT appears on the display after any key is pressed Recharge batteries by plugging in the power supply CAUTION Using the wrong battery types can cause damage The Fronius Personal Display DL requires t...

Page 40: ...apter to the power supply unit Charge the batteries until the segment bars on the display show a state of charge of 100 Battery disposal Defective batteries should only be disposed of in accordance wi...

Page 41: ...d from the display by press ing the Esc key IMPORTANT The display can save up to 8 inverter errors Confirming the service code by pressing the Esc key will display the next service code if any Trouble...

Page 42: ...the ADD IG menu item in the Setup menu of the Fronius Personal Display DL Disconnect and then reinsert the Solar Net cable at the Fro nius Personal Display DL Box Press the Enter key within 10 second...

Page 43: ...ly one Fronius Personal Display DL can communicate with the available system inverters Remedy When the Fronius Personal Display DL is replaced by a new one delete all system inverters from the configu...

Page 44: ...sions 7 5 x 4 5 x 2 1 in 190 x 114 x 53 mm Nominal voltage 208 230 240 V AC Degree of protection integrated into the inverter as per the inverter s operating instructions Operating temperature 4 to 12...

Page 45: ...43 EN US...

Page 46: ...44...

Page 47: ...45 EN US...

Page 48: ...ll addresses of our sales branches and partner firms Fronius International GmbH 4600 Wels Froniusplatz 1 Austria E Mail pv fronius com http www fronius com Fronius USA LLC Solar Electronics Division 1...