Troubleshooting
Troubleshooting
No welding current
Power source switched on, power source indication illuminates, shielding gas present
Incorrect ground connection
Establish proper ground connection
Power cable in welding torch damaged or broken.
Replace welding torch
Cause:
Remedy:
Cause:
Remedy:
No function after pressing torch trigger
Power source switched on, power source indication illuminates
FSC (‘Fronius System Connector’—central connector) not inserted up to the
stop
Insert FSC up to the stop
Welding torch or welding torch control line faulty
Replace welding torch
Interconnecting hosepack not properly connected or faulty
Connect interconnecting hosepack properly
Replace faulty interconnecting hosepack
Faulty power source
Notify service provider
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
No shielding gas
All other functions present
Gas cylinder empty
Change gas cylinder
Gas pressure regulator faulty
Replace gas pressure regulator
Gas hose kinked, damaged, or not attached
Attach and straighten gas hose. Replace faulty gas hose
Welding torch faulty
Replace welding torch
Gas solenoid valve faulty
Contact service team (have gas solenoid valve replaced)
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
40
Summary of Contents for MTG 2100 S
Page 2: ......
Page 24: ...24 ...
Page 39: ...Clean wearing parts using compressed air 2 3 Recommended Replace the inner liner 39 EN US ...
Page 46: ...46 ...
Page 83: ...Nettoyer les pièces d usure à l air comprimé 2 3 Recommandé changer la gaine guide fil 83 FR ...
Page 90: ...90 ...
Page 112: ...112 ...
Page 134: ...134 ...
Page 135: ...135 PT BR ...