67
EN
In addition to the operating instructions, any generally applicable and local regulations re-
garding accident prevention and environmental protection must be provided and followed.
All safety and danger notices on the LaserHybrid head must be kept in a legible condition.
Safety measures
at the installation
location
The cell for the LaserHybrid welding process must meet the following requirements:
-
be sealed off from adjoining rooms to make it lightproof
-
be screened with min. 1 mm thick steel plate and/or approved laser protective glass
to prevent any UV or laser radiation escaping
-
both the laser welding process and the arc welding process must stop automatically
as soon as the cell is opened
A device that topples over can easily kill someone. Place the device on a solid, level sur-
face.
-
The maximum permissible tilt angle is 10°.
Special regulations apply in rooms at risk of fire or explosion
-
Observe relevant national and international regulations.
Use internal directives and checks to ensure that the workplace environment is always
clean and clearly laid out.
Only set up and operate the device in accordance with the degree of protection shown on
the rating plate.
When setting up the device, ensure there is an all-round clearance of 0.5 m (1 ft. 7.69 in.)
to ensure that cooling air can flow in and out freely.
When transporting the device, observe the relevant national and local guidelines and ac-
cident prevention regulations. This applies especially to guidelines regarding the risks aris-
ing during transport.
Before transporting the device, allow coolant to drain completely and detach the following
components:
-
Wire feed speed
-
Wirespool
-
Shielding gas cylinder
After transporting the device, the device must be visually inspected for damage before
commissioning. Any damage must be repaired by trained service technicians before com-
missioning the device.
Safety measures
in normal opera-
tion
Only operate the LaserHybrid head if all protection and safety devices are fully functional.
If the safety devices are not fully functional, there is a risk of
-
injury or death to the operator or a third party,
-
damage to the device and other material assets belonging to the operator,
-
inefficient operation of the device.
Any safety devices that are not functioning properly must be repaired before switching on
the device.
Never bypass or disable safety devices.
Before starting up the LaserHybrid head, ensure that no one is likely to be endangered.
Check the LaserHybrid head at least once a week for obvious damage and proper func-
tioning of the safety devices.
Summary of Contents for LaserHybrid
Page 2: ...2 ...
Page 4: ...4 ...
Page 54: ...54 Gesamtschaltplan Schaltplan ...
Page 56: ...56 ...
Page 58: ...58 ...
Page 107: ...107 EN Entire circuit diagram Circuit diagram ...
Page 110: ...110 ...
Page 160: ...160 Schéma d ensemble des connexions Schéma de connexions ...
Page 162: ...162 ...
Page 163: ......
Page 167: ...167 ...
Page 168: ...168 ...
Page 171: ...171 ...
Page 174: ...174 ...
Page 175: ...175 ...
Page 176: ...176 ...
Page 177: ...177 ...
Page 178: ...178 ...
Page 179: ...179 ...
Page 180: ...180 ...
Page 181: ...181 ...
Page 182: ...182 ...
Page 183: ...183 ...