Code
Description
Behaviour
Remedy
313
Battery input voltage too high.
Short-term interruption
while feeding energy into
the grid.
The inverter repeats its
startup routine. This ser-
vice code may occur
sporadically even though
there is no actual fault.
Switch on, connect
or check battery;
*)
314,
315
Internal system error
Short-term interruption
while feeding energy into
the grid.
The inverter repeats its
startup routine.
*)
318
Solar module return current de-
tected
324
DC module overtemperature
(battery)
Short-term interruption
while feeding energy into
the grid.
The inverter repeats its
startup routine.
Purge cooling air
openings and heat
sink; **)
*) If the status code is displayed all the time: Notify a Fronius-trained service technician.
**) Fault is rectified automatically. If this status code keeps recurring, contact your system fitter
Status codes –
Class 4
Some of the class 4 status codes necessitate intervention by a Fronius-trained
service engineer.
Code
Description
Behaviour
Remedy
401
Unable to communicate with the
power stage set
The inverter will auto-
matically attempt to
connect again and, if
possible, will resume
feeding energy into the
grid.
*)
406
DC module temperature sensor
faulty (PV)
407
AC module temperature sensor
faulty
408
DC component measured in the
grid too high
412
Fixed voltage mode has been selec-
ted instead of MPP voltage mode,
and the fixed voltage has been set
to too low or too high a value.
-
**)
415
Safety cut-out via option card or
RECERBO has triggered
The inverter is not feed-
ing any energy into the
grid.
*)
416
No communication possible
between power stage set and con-
trol system.
The inverter will auto-
matically attempt to
connect again and, if
possible, will resume
feeding energy into the
grid.
*)
125
EN
Summary of Contents for Energy Package
Page 2: ......
Page 10: ...10...
Page 11: ...General information 11...
Page 12: ...12...
Page 37: ...Operation 37...
Page 38: ...38...
Page 69: ...Fronius system monitoring 69...
Page 70: ...70...
Page 82: ...82...
Page 83: ...Current data services and settings offered by Fronius system monitor ing 83...
Page 84: ...84...
Page 121: ...Troubleshooting and maintenance 121...
Page 122: ...122...
Page 136: ...136...
Page 137: ...Appendix 137...
Page 138: ...138...
Page 145: ...145 EN...
Page 146: ...146...
Page 147: ...147 EN...
Page 148: ......