General information for the network administrator
Requirements
Configuring a network for Fronius Datamanager 2.0 requires knowledge of network tech-
nology.
If Fronius Datamanager 2.0 is being integrated into an existing network, the Fronius
Datamanager 2.0 address must be adapted to the network.
Example: network address range = 192.168.1.x, subnet mask = 255.255.255.0
-
An IP address between 192.168.1.1 and 192.168.1.254 must be assigned to Fronius
Datamanager 2.0.
-
The IP address selected may not be already assigned in the network.
-
The subnet mask must correspond to the existing network (e.g., 255.255.255.0).
If Fronius Datamanager 2.0 will be sending service messages and/or data to Fronius
Solar.web, then a gateway address and a DNS server address must also be entered.
Fronius Datamanager 2.0 uses the gateway address to access the internet. The IP ad-
dress of the DSL router can be used as a gateway address, for example.
IMPORTANT!
-
Fronius Datamanager 2.0 may not have the same IP address as the PC/laptop!
-
Fronius Datamanager 2.0 cannot connect itself to the internet. A router must be
used for a DSL connection to the internet.
General Firewall
Settings
DSL routers mostly enable you to send data to the internet and, therefore, do not nor-
mally have to be configured.
Server addresses for data transfer
If a firewall is used for outgoing connections, the following protocols, server addresses
and ports must be allowed for successful data transfer:
-
Tcp fronius-se-iot-dm-1.azure.devices.net:8883
-
Tcp fronius-se-iot-dm-1.azure.devices.net:443
-
Tcp fronius-se-iot-dm-2.azure.devices.net:8883
-
Tcp fronius-se-iot-dm-2.azure.devices.net:443
-
Tcp fronius-se-iot-dm-1.telemetry.azure.devices.net:8883
-
Tcp fronius-se-iot-dm-1.telemetry.azure.devices.net:443
-
Tcp fronius-se-iot-dm-2.telemetry.azure.devices.net:8883
-
Tcp fronius-se-iot-dm-2.telemetry.azure.devices.net:443
-
Fdmp-solarweb.com:49049 (dm local port 54321)
-
Tcp http://www3.fronius.com:80
-
Tcp ftp://transfer.fronius.com:21
-
Tcp provisioning-lite.solarweb.com:443
-
Tcp froniusseiot.blob.core.windows.net:443
If existing firewall rules block the connection to the Fronius system monitoring, the follow-
ing firewall rules must be added:
49049/UDP
output
80/TCP *)
input
Sending service messages
x
-
Connecting to Datamanager via Fronius Solar.web
x
-
19
EN-US
Summary of Contents for Datamanager 2.0
Page 2: ......
Page 6: ...6 ...
Page 7: ...General information 7 ...
Page 8: ...8 ...
Page 30: ...30 ...
Page 31: ...Installing Fronius Datamanager 2 0 31 ...
Page 32: ...32 ...
Page 34: ...The next slot must be kept free Never remove an existing ENS plug in card ENS Datamanager 34 ...
Page 49: ...Establishing a Connection to Froni us Datamanager 2 0 49 ...
Page 50: ...50 ...
Page 53: ...Current Data Services and Settings on Fronius Datamanager 2 0 53 ...
Page 54: ...54 ...
Page 86: ...86 ...
Page 87: ...87 EN US ...
Page 88: ... ...