3
Connect the welding torch to the welding system
4
Remove the gas nozzle from the welding torch
5
Thread the wire
The welding wire should protrude approx. 200 mm from the contact tip.
6
Thread the welding wire into the intake part of the sensor
7
Use clamps to secure the welding torch in the welding wire calibration system
at the contact tip
8
Make sure that the torch hosepack is arranged as straight as possible
Connecting the
computer to the
calibration sys-
tem and signa-
ture pad
1
Connect the USB connection cable to the calibration system and the com-
puter / laptop
2
Connect the Signotec signature pad to the calibration system
3
Switch on the power source
Preparing the
gas calibration
system
IMPORTANT!
If a shielding gas supply is to be calibrated, it must be connected
to the calibration system before starting the calibration process.
The welding system and calibration system must be connected to each other.
1
1
1
Connect the gas hose to the pres-
sure regulator and to the Gas IN
connection on the calibration sys-
tem
max. supply pressure: 5 bar
2
2
2
Connect the gas hose to the
wirefeeder or the power source
and to the Gas OUT connection on
the calibration system
54
Summary of Contents for Calibration system 2.0
Page 2: ......
Page 13: ...General information 13...
Page 14: ...14...
Page 22: ...22...
Page 23: ...Controls connections and mechan ical components 23...
Page 24: ...24...
Page 28: ...28...
Page 29: ...Installation 29...
Page 30: ...30...
Page 38: ...38...
Page 39: ...Calibrating welding systems 39...
Page 40: ...40...
Page 47: ...2 2 Connect the Signotec signature pad to the calibration system 47 EN...
Page 90: ...90...
Page 91: ...Troubleshooting 91...
Page 92: ...92...
Page 95: ...Technical data 95...
Page 96: ...96...
Page 99: ...99 EN...