Changing net-
work settings
1
Setting network settings
a
)
via the calibration software:
or
b
)
under the network settings (TCP/IPv4) of the adapter:
Internet protocol, version 4 (TCP/IPv4) Properties
Changing the
network settings
for USB calibra-
tion
IMPORTANT!
Prerequisites for USB calibration:
-
DHCP server, which starts automatically when the program starts.
-
.net Framework, at least version 4.7.2
1
Specify network settings for USB calibration
a
)
Via the calibration software:
Settings / Configure network adapter / SpeedNet / Ethernet ...
or
b
)
From the network settings (TCP/IPv4) of the adapter:
Use the following IP address: 192.168.125.200
2
Check if the IP address 192.168.125.1 is displayed on the power source
34