Control Panel
(1)
(2)
(3)
(4)
(5)
(6)(7)
(15)
(14)
(13)
(12)
(11)
(10)
(8)
(9)
No.
Function
(1)
Left parameter selection button
(2)
Right parameter selection button
Buttons (1) and (2) are used to select the following process parameters:
Starting current for the plasma process
UpSlope
Period of time it takes to rise from the starting current I
start
to the spe-
cified main current I
main
during the plasma process.
Main current for the plasma process
DownSlope
Period of time it takes to fall from the specified main current I
main
to the
final current I
end
during the plasma process.
Final current for the plasma process
Job number
In job mode, for retrieving saved parameter sets by job numbers.
Diameter of electrode
For entering the diameter of the tungsten electrode for the plasma pro-
cess