Servicing the system | 5
B1510622_en | Operating instructions Firewood boiler S4 Turbo
67
5.4.2 Checking the condensation drain
NOTICE! If the condensation drain is blocked, the condensing boiler heat
exchanger will fill with condensation, thus preventing the flue gas from escaping
through the chimney, which could in turn lead to problems with combustion. For
this reason it is important to check the condensation drain regularly!
At the back of the boiler below the condensing boiler heat exchanger:
r
Position a suitable container below the siphon to catch the condensation that runs out
r
Remove and check the siphon for dirt and deposits
r
Check the condensation drain up to where it enters the waste water system and clean
if necessary
r
Ensure that the condensation is continually drained into the waste water system!