Connection / Name
Note
KM-31
Mixing valve heating circuit 1
KM-32
Heating circuit pump 2
Connection cable
1)
3 x 1.5 mm
2
, max. 2.5A / 500W
KM-33
Heating circuit pump 1
KM-34
Heating circuit pump 0
or burner relay
Connection cable
1)
3 x 1.5 mm
2
, max. 3A / 600VA
KM-35
Operating signal
Connection cable
1)
2 x 0.75 mm
2
⇨ See "Operating signal" [page 13]
KM-36
Optional module
1.YMM as per ÖVE-K41-5 or H05VV-F as per DIN VDE 0881-5
2.1.2 Mains connection
Connect the power supply at the "Mains connection" plug
❒ Flexible sheathed cable must be used for the wiring; this must be of the correct size to comply with
applicable regional standards and regulations.
Boiler type
Electric fuses
Fuse type
S1 Turbo
16A
C16A
S1 Turbo F
16A
C16A
S3 Turbo
13A
C13A
S4 Turbo
16A
C16A
S4 Turbo F
16A
C16A
2.1.3 Connecting the outside temperature sensor
The outside temperature sensor is included with the materials supplied for the boiler and is usually mounted on
an outer wall that is not directly exposed to the sun. It continuously measures the ambient temperature and
forms part of the weather-compensated heating circuit control.
KM-19 / Außenfühler
Power connection and wiring
2
Core module and connection options
Service manual Lambdatronic SP 3200 for dual fuel boiler | B1460720_en